• ASTM F 1259M : 1996 : R2003

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Standard Guide for Design of Flat, Straight-Line Test Structures for Detecting Metallization Open-Circuit or Resistance-Increase Failure Due to Electromigration [Metric] (Withdrawn 2009)

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  31-12-2009

    Language(s):  English

    Published date:  10-06-1996

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 10.04, 2009 Covers recommended design features and is used in accelerated stress tests to characterize the failure distribution of interconnect metallizations that fail due to electromigration, and is restricted to structures with a straight test line on a flat surface.

    Scope - (Show below) - (Hide below)

    1.1 This guide covers recommended design features for test structures used in accelerated stress tests, as described in Test Method F 1260M, to characterize the failure distribution of interconnect metallizations that fail due to electromigration.

    1.2 This guide is restricted to structures with a straight test line on a flat surface that are used to detect failures due to an open-circuit or a percent-increase in resistance of the test line.

    1.3 This guide is not intended for testing metal lines whose widths are approximately equal to or less than the estimated mean size of the metal grains in the metallization line.

    1.4 This guide is not intended for test structures used to detect random defects in a metallization line.

    1.5 Metallizations tested and characterized are those that are used in microelectronic circuits and devices.

    General Product Information - (Show below) - (Hide below)

    Committee F 01
    Document Type Guide
    Product Note Reconfirmed 2003
    Publisher American Society for Testing and Materials
    Status Withdrawn
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM F 1260M : 1996 Standard Test Method for Estimating Electromigration Median Time-To-Failure and Sigma of Integrated Circuit Metallizations [Metric]
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective