ASTM F 1608 : 2016 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Microbial Ranking of Porous Packaging Materials (Exposure Chamber Method)
04-01-2022
English
01-05-2016
CONTAINED IN VOL. 15.09, 2016 Specifies the passage of airborne bacteria through porous materials intended for use in packaging sterile medical devices.
Committee |
F 02
|
DocumentType |
Redline
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This test method is used to determine the passage of airborne bacteria through porous materials intended for use in packaging sterile medical devices. This test method is designed to test materials under conditions that result in the detectable passage of bacterial spores through the test material.
1.1.1A round-robin study was conducted with eleven laboratories participating. Each laboratory tested duplicate samples of six commercially available porous materials to determine the Log Reduction Value (LRV) (see calculation in Section 12). Materials tested under the standard conditions described in this test method returned average values that range from LRV 1.7 to 4.3.
1.1.2Results of this round-robin study indicate that caution should be used when comparing test data and ranking materials, especially when a small number of sample replicates are used. In addition, further collaborative work (such as described in Practice E691) should be conducted before this test method would be considered adequate for purposes of setting performance standards.
1.2This test method requires manipulation of microorganisms and should be performed only by trained personnel. The U.S. Department of Health and Human Services publication Biosafety in Microbiological and Biomedical Laboratories (CDC/NIH-HHS Publication No. 84-8395) should be consulted for guidance.
1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
CSA Z314.14 : 2015 | SELECTION AND USE OF PACKAGING (STERILE BARRIER SYSTEMS) IN HEALTHCARE SETTINGS |
ASTM F 1585 : 2000 | Standard Guide for Integrity Testing of Porous Barrier Medical Packages (Withdrawn 2006) |
AAMI ST77 : 2013 | CONTAINMENT DEVICES FOR REUSABLE MEDICAL DEVICE STERILIZATION |
ASTM F 2097 : 2016 : REDLINE | Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products |
BS EN 868-1:1997 | Packaging materials and systems for medical devices which are to be sterilized General requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.