• There are no items in your cart

ASTM F 1801 : 1997 : R2014

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Corrosion Fatigue Testing of Metallic Implant Materials

Available format(s)

Hardcopy , PDF

Superseded date

27-10-2020

Superseded by

ASTM F 1801 : 2020

Language(s)

English

Published date

27-11-2014

€67.30
Excluding VAT

CONTAINED IN VOL. 13.01, 2015 Describes the procedure for performing corrosion fatigue tests to obtain S-N fatigue curves or statistically derived fatigue strength values, or both, for metallic implant materials.

Committee
F 04
DocumentType
Standard Practice
Pages
7
ProductNote
Reconfirmed 2014
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice covers the procedure for performing corrosion fatigue tests to obtain S-N fatigue curves or statistically derived fatigue strength values, or both, for metallic implant materials. This practice describes the testing of axially loaded fatigue specimens subjected to a constant amplitude, periodic forcing function in saline solution at 37°C and in air at room temperature. The environmental test method for implant materials may be adapted to other modes of fatigue loading such as bending or torsion. While this practice is not intended to apply to fatigue tests on implantable components or devices, it does provide guidelines for fatigue tests with standard specimens in an environment related to physiological conditions.

1.2The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F 86 : 2013 : REDLINE Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants
ASTM E 1012 : 2014 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
ASTM E 466 : 2015 : REDLINE Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials
ASTM E 1012 : 1999 Standard Practice for Verification of Specimen Alignment Under Tensile Loading
ASTM E 1012 : 2012 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
ASME B46.1 : 2009 SURFACE TEXTURE (SURFACE ROUGHNESS, WAVINESS, AND LAY)
ASTM E 1012 : 2014 : EDT 1 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
ASTM E 1012 : 2012 : EDT 1 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
ASTM E 1012 : 2005 Standard Practice for Verification of Test Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application
ASTM E 1012 : 2019 Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.