ASTM F 1867 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
![header thumbnail](/images/publishers\astm_cover.gif)
Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation
Hardcopy , PDF
11-11-2014
English
15-03-2006
CONTAINED IN VOL. 08.04, 2018 Defines the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe.
Committee |
F 17
|
DocumentType |
Standard Practice
|
Pages |
6
|
ProductNote |
Reconfirmed 2006
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This practice covers the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, and process piping.
1.2 This practice is to be used with the material specified in Section of Specification F 1871.
1.3 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4 There is no similar or equivalent ISO Standard.
ASTM F 1871 : 2018 | Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation |
ASTM D 790 : 2017 : REDLINE | Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials |
ASTM D 2122 : 2016 : REDLINE | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM F 1871 : 2011-06 | SPECIFICATION FOR FOLDED/FORMED POLY (VINYL CHLORIDE) PIPE TYPE A FOR EXISTING SEWER AND CONDUIT REHABILITATION |
ASTM D 648 : 2016 | Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position |
ASTM D 638 : 2014 : REDLINE | Standard Test Method for Tensile Properties of Plastics |
ASTM D 1784 : 2011 : REDLINE | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.