ASTM F 2096 : 2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Detecting Gross Leaks in Packaging by Internal Pressurization (Bubble Test)
Hardcopy , PDF
19-02-2020
English
15-12-2011
CONTAINED IN VOL. 15.10, 2015 Defines the detection of gross leaks in packaging. Method sensitivity is down to 250 [mu]m (0.010 in.) with an 81% probability.
Committee |
F 02
|
DocumentType |
Test Method
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This test method covers the detection of gross leaks in packaging. Method sensitivity is down to 250 μm (0.010 in.) with an 81 % probability (see Section 11). This test method may be used for tray and pouch packages.
1.2 The sensitivity of this test method has not been evaluated for use with porous materials other than spunbonded polyolefin or with nonporous packaging.
1.3 This test method is destructive in that it requires entry into the package to supply an internal air pressure
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2097 : 2016 | Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products |
S.R. CEN ISO/TS 16775:2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 (ISO/TS 16775:2014) |
CAN/CSA-ISO/TS 16775:17 | Packaging for terminally sterilized medical devices — Guidance on the application of ISO 11607-1 and ISO 11607-2 (Adopted ISO technical specification 16775:2014, first edition, 2014-05-15) |
CEN ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices - Guidance on the application of ISO 11607-1 and ISO 11607-2 (ISO/TS 16775:2014) |
PD CEN ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices. Guidance on the application of ISO 11607-1 and ISO 11607-2 |
ASTM F 2097 : 2016 : REDLINE | Standard Guide for Design and Evaluation of Primary Flexible Packaging for Medical Products |
ANSI/AAMI/ISO TIR16775:2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 |
ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices Guidance on the application of ISO 11607-1 and ISO 11607-2 |
UNI CEN ISO/TS 16775 : 2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.