ASTM F 2136 : 2001
NA
Status of Standard is Unknown
Standard Test Method for Notched, Constant Ligament-Stress (NCLS) Test to Determine Slow-Crack-Growth Resistance of HDPE Resins or HDPE Corrugated Pipe
Hardcopy , PDF
English
10-08-2001
Committee |
F 17
|
DocumentType |
Test Method
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
NA
|
SupersededBy |
1.1 This test method is used to determine the susceptibility of high-density polyethylene (HDPE) resins or corrugated pipe to slow-crack-growth under a constant ligament-stress in an accelerating environment. This test method is intended to apply only to HDPE of a limited melt index and density range as defined in AASHTO Standard Specification M 294. This test method may be applicable for other materials, but data are not available for other materials at this time.
1.2 This test method measures the failure time associated with a given test specimen at a constant, specified, ligament-stress level.
1.3 The values stated in inch-pound units are to be regarded as the standard. Values given in parentheses are for information only.
1.4 Definitions are in accordance with Terminology F 412, and abbreviations are in accordance with Terminology D 1600, unless otherwise specified.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2987 : 2012 : R2018 | Standard Specification for Corrugated Polyethylene Pipe and Fittings for Mine Heap Leach Aeration Applications (Withdrawn 2024) |
ASTM F 2306/F2306M : 2019 | Standard Specification for 12 to 60 in. [300 to 1500 mm] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Gravity-Flow Storm Sewer and Subsurface Drainage Applications |
ASTM F 2986 : 2012 : R2017 | Standard Specification for Corrugated Polyethylene Pipe and Fittings for Mine Leachate Applications |
ASTM F 2764/F2764M : 2019 | Standard Specification for 6 to 60 in. [150 to 1500 mm] Polypropylene (PP) Corrugated Double and Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications |
ASTM F 2947/F2947M : 2019 | Standard Specification for 150 to 1500 mm [6 to 60 in.] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Sanitary Sewer Applications |
ASTM F 2562/F2562M : 2015 | Specification for Steel Reinforced Thermoplastic Ribbed Pipe and Fittings for Non-Pressure Drainage and Sewerage |
ASTM F 3181 : 2016 | Standard Test Method for The Un-notched, Constant Ligament Stress Crack Test (UCLS) for HDPE Materials Containing Post- Consumer Recycled HDPE |
ASTM F 2648/F2648M : 2017 | Standard Specification for 2 to 60 inch [50 to 1500 mm] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications |
ASTM F 2435 : 2015 | Standard Specification for Steel Reinforced Polyethylene (PE) Corrugated Pipe |
ASTM F 2763 : 2016 | Standard Specification for 12 to 60 in. [300 to 1500 mm] Dual and Triple Profile-Wall Polyethylene (PE) Pipe and Fittings for Sanitary Sewer Applications |
ASTM F 2922 : 2013 : R2018 | Standard Specification for Polyethylene (PE) Corrugated Wall Stormwater Collection Chambers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.