ASTM F 2419 : 2011 : R2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring
Hardcopy , PDF
11-11-2021
English
10-01-2018
CONTAINED IN VOL. 15.04, 2018 Defines the installation and preparation of the thick poured gypsum concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured gypsum concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.
Committee |
F 06
|
DocumentType |
Standard Practice
|
Pages |
3
|
ProductNote |
Reconfirmed 2017
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice covers the installation and preparation of the thick poured gypsum concrete underlayments over wood structural panel subfloors in commercial structures or over concrete floors in commercial structures and the preparation of the thick poured gypsum concrete underlayment surface prior to the installation of resilient flooring in commercial buildings.
1.2This practice covers the factors that are required to be controlled while installing thick poured gypsum concrete underlayment as a base for resilient flooring.
1.3This practice does not cover the structural adequacy of the wood structural panel subfloor or concrete subfloor. The structural integrity of assemblies is governed by local building codes.
1.4This practice does not supersede in any manner the thick poured gypsum concrete underlayment manufacturers, adhesive manufacturer’s or resilient flooring manufacturer’s written instructions. Consult the individual manufacturer for specific recommendations.
1.5Thick poured gypsum concrete underlayments are not suitable for use on concrete slabs on ground due to potential moisture problems arising from moisture intrusion, unless an adequate vapor retarder or vapor barrier is present directly beneath the concrete subfloor.
1.6The values stated in inch-pound units are to be regarded as standard. The values stated in parentheses are approximate mathematical conversions to SI units, which are provided for information only.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F 2678 : 2016 | Standard Practice for Preparing Panel Underlayments, Thick Poured Gypsum Concrete Underlayments, Thick Poured Lightweight Cellular Concrete Underlayments, and Concrete Subfloors with Underlayment Patching Compounds to Receive Resilient Flooring |
ASTM F 1482 : 2004 : R2009 : EDT 1 | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM F 1482 : 2015 | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM F 1482 : 2015 : REDLINE | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM D 4263 : 1983 : R2005 | Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method |
ASTM D 4263 : 1983 : R1999 | Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method |
ASTM F 1482 : 2004 | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM F 1482 : 2003 | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM D 4263 : 1983 : R2012 | Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method |
ASTM F 1482 : 2021 | Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring |
ASTM F 1482 : 1994 : REV A | Standard Guide to Wood Underlayment Products Available for Use Under Resilient Flooring |
ASTM D 4263 : 1983 : R2018 | Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.