• There are no items in your cart

ASTM F 2510/F2510M : 2022

Current

Current

The latest, up-to-date edition.

Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures and Corrugated Dual- and Triple-Wall Polyethylene and Polypropylene Pipes

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

14-03-2022

€49.35
Excluding VAT

Committee
F 17
DocumentType
Standard
Pages
3
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This specification covers the design, material, and minimum performance requirements of resilient connectors used for connections between reinforced concrete structures conforming to Specifications C478/C478M and C913 to annular corrugated profile wall high density polyethylene (HDPE) and polypropylene (PP) drainage and sewer pipe conforming to Specifications F2306/F2306M, F2648/F2648M, F2763/F2763M, F2764/F2764M, F2881/F2881M and F2947/F2947M.

1.1.1These connectors are designed to provide a positive seal between the pipe and manholes or other structures subjected to internal and external hydrostatic pressures less than 10.8 psi [74 KPa].

1.1.2Testing under this standard is limited to hydrostatic pressures. Alternate air and vacuum pressure testing involve unique testing protocols and are not addressed under this standard.

1.1.3Testing under this standard is conducted in a laboratory as a proof of design certification. Actual field performance testing would be accomplished and accepted under individual project performance standards or pipeline acceptance criteria, which is outside the scope of this standard.

Note 1:Infiltration or exfiltration quantities for an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities must be covered by other specifications and suitable testing of the installed pipeline and system.

Note 2:This specification may be applied to other types of plastic drainage pipe. Consult with manufacturer of pipe for applicability to this standard.

1.2The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI units are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.3The following precautionary caveat pertains only to the test methods portion, Section 7. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precaution statement, see 7.2.3.

1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM C 1821/C1821M : 2016 : R2021 : EDT 1 Standard Practice for Installation of Underground Circular Precast Concrete Manhole Structures

ASTM F 412 : 2024 Standard Terminology Relating to Plastic Piping Systems
ASTM F 2764/F2764M : 2024 Standard Specification for 6 in. to 60 in. [150 mm to 1500 mm] Polypropylene (PP) Corrugated Double and Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
ASTM C 913 : 2021 Standard Specification for Precast Concrete Water and Wastewater Structures
ASTM F 412 : 2021 Standard Terminology Relating to Plastic Piping Systems
ASTM F 2648/F2648M : 2020 Standard Specification for 2 to 60 inch [50 to 1500 mm] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications
ASTM C 478/C478M : 2022 Standard Specification for Circular Precast Reinforced Concrete Manhole Sections
ASTM C 913 : 2023 Standard Specification for Precast Concrete Water and Wastewater Structures
ASTM F 2764/F2764M : 2019 Standard Specification for 6 to 60 in. [150 to 1500 mm] Polypropylene (PP) Corrugated Double and Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
ASTM F 2648/F2648M : 2022 Standard Specification for 50 mm to 1500 mm [2 in. to 60 in.] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications
ASTM A 493 : 2016 Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging
ASTM F 2648/F2648M : 2023 Standard Specification for 50 mm to 1500 mm [2 in. to 60 in.] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications
ASTM C 478/C478M : 2020 Standard Specification for Circular Precast Reinforced Concrete Manhole Sections
ASTM A 493 : 2023 Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold Forging
ASTM A 666 : 2015 Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar
ASTM F 412 : 2023 Standard Terminology Relating to Plastic Piping Systems
ASTM F 2764/F2764M : 2023 Standard Specification for 6 in. to 60 in. [150 mm to 1500 mm] Polypropylene (PP) Corrugated Double and Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications
ASTM A 666 : 2023 Standard Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat Bar
ASTM D 746 : 2020 Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact
ASTM D 746 : 2024 Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.