ASTM F 2561 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner
Hardcopy , PDF
30-07-2020
English
01-12-2017
Committee |
F 17
|
DocumentType |
Standard Practice
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner diameter of 3 to 12 in. (7.6 to 30.5 cm) and its connection to the main pipe having an inner diameter of 6 to 24 in. (15.2 to 61.0 cm) and up the lateral a maximum of 150 ft without excavation. The lateral pipe is accessed remotely from the main pipe and from a lateral access point. This will be accomplished by the installation of a resin impregnated one-piece main and lateral cured-in-place lining (MLCIPL) by means of air inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe, providing a verifiable non-leaking structural connection and seal.
1.2The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3There is no similar or equivalent ISO Standard.
1.4Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. Users should be aware that selling mercury or mercury-containing products, or both, may be prohibited by local or national law.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F 3240 : 2019 : EDT 1 | Standard Practice for Installation of Seamless Molded Hydrophilic Gaskets (SMHG) for Long-Term Watertightness of Cured-in-Place Rehabilitation of Main and Lateral Pipelines |
ASTM F 3240 : 2017 | Standard Practice for Installation of Seamless Molded Hydrophilic Gaskets (SMHG) for Long-Term Watertightness of Cured-in-Place Rehabilitation of Main and Lateral Pipelines |
ICC IPC International Plumbing Code : 2021 | International Plumbing Code |
ASTM D 1600 : 1999 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM F 1216 : 2016 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM F 1216 : 2007 : REV B | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 5813 : 2004 : R2008 | Standard Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems |
ASTM D 3681 : 2006 | Standard Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM F 1216 : 2009 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM F 3097 : 2015 | Standard Practice for Installation of an Outside Sewer Service Cleanout through a Minimally Invasive Small Bore Vacuum Excavation |
ASTM F 1216 : 2008 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 3681 : 2001 : EDT 1 | Standard Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM D 1600 : 2007 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM F 1216 : 1998 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 1600 : 2013 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 3681 : 2018 | Standard Test Method for Chemical Resistance of “Fiberglass” (Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM F 1216 : 2006 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 1600 : 2014 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 5813 : 2004 : R2018 | Standard Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems |
ASTM D 1600 : 2008 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM F 1216 : 2007 : REV A | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 5813 : 2004 | Standard Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems |
ASTM D 3681 : 2012 : EDT 1 | Standard Test Method for Chemical Resistance of “Fiberglass” (Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM D 1600 : 2018 | Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024) |
ASTM F 1216 : 2005 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 3681 : 2001 | Standard Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM D 3681 : 1996 | Standard Test Method for Chemical Resistance of "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM F 1216 : 2007 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 5813 : 1995 | Standard Specification for Cured-In-Place Thermosetting Resin Sewer Pipe |
ASTM D 3681 : 2012 | Standard Test Method for Chemical Resistance of “Fiberglass” (Glass–Fiber–Reinforced Thermosetting-Resin) Pipe in a Deflected Condition |
ASTM F 1216 : 2003 | Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube |
ASTM D 5813 : 2004 : R2012 | Standard Specification for Cured-In-Place Thermosetting Resin Sewer Piping Systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.