ASTM F 2695 : 2012 : REDLINE
Current
The latest, up-to-date edition.
Standard Specification for Ultra-High Molecular Weight Polyethylene Powder Blended With Alpha-Tocopherol (Vitamin E) and Fabricated Forms for Surgical Implant Applications
English
15-05-2012
CONTAINED IN VOL. 13.01, 2012 Defines ultra-high molecular weight polyethylene (UHMWPE) powder blended with alpha-tocopherol (vitamin E) intended for use in surgical implants.
Committee |
F 04
|
DocumentType |
Redline
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1 This specification covers ultra-high molecular weight polyethylene (UHMWPE) powder blended with alpha-tocopherol (vitamin E) intended for use in surgical implants.
1.2 The requirements of this specification apply to alpha-tocopherol-containing UHMWPE in two forms. One is virgin polymer powder blended with alpha-tocopherol prior to consolidation (Section 4). The second is any form fabricated from this blended, alpha-tocopherol-containing powder from which a finished product is subsequently produced (Section 5). This specification does not apply to finished or semi-finished products that are doped with vitamin E after consolidation.
1.3 Aside from blending with alpha-tocopherol, the provisions of Specifications F648 and D4020 apply. Special requirements detailed in this specification are added to describe powders containing alpha-tocopherol that will be used in surgical implants. This specification addresses material characteristics and does not apply to the packaged and sterilized finished implant. This specification also does not apply to UHMWPE materials extensively crosslinked by gamma and electron beam sources of ionizing radiation.
1.4 The following precautionary caveat pertains only to the fabricated forms portion, Section 5, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 2759 : 2011 : REDLINE | Standard Guide for Assessment of the Ultra High Molecular Weight Polyethylene (UHMWPE) Used in Orthopedic and Spinal Devices |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 3451-1:2008 | Plastics Determination of ash Part 1: General methods |
ASTM F 756 : 2017 : REDLINE | Standard Practice for Assessment of Hemolytic Properties of Materials |
ASTM F 749 : 2013 : REDLINE | Standard Practice for Evaluating Material Extracts by Intracutaneous Injection in the Rabbit |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 10993-8:2000 | Biological evaluation of medical devices Part 8: Selection and qualification of reference materials for biological tests |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ASTM F 619 : 2014 : REDLINE | Standard Practice for Extraction of Medical Plastics |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ASTM D 790 : 2017 : REDLINE | Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials |
ASTM F 748 : 2016 : REDLINE | Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ASTM D 648 : 2016 | Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ASTM F 648 : 2014 : REDLINE | Standard Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.