ASTM F 2888 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Platelet Leukocyte Count—An In-Vitro Measure for Hemocompatibility Assessment of Cardiovascular Materials
Hardcopy , PDF
21-02-2019
English
15-02-2013
CONTAINED IN VOL. 13.02, 2013 Defines the evaluation of cardiovascular device materials for their ability to induce thrombus formation.
Committee |
F 04
|
DocumentType |
Test Method
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This test method assists in the evaluation of cardiovascular device materials for their ability to induce thrombus formation. Thrombus formation is assessed by means of a reduction in human platelets and leukocytes when consumed by thrombus after activation on the material surface. This assay may be part of the hemocompatibility evaluation for devices and materials contacting human blood, as per ANSI/AAMI/ISO 10993–4. See also Test Method F2382.
1.2All safety policies and practices shall be observed during the performance of this test method. All human blood and any materials that had contact with human blood shall be bagged in a biohazard bag, properly labeled as the contents, and disposed of by appropriate means.
1.3The human blood should be handled at Biosafety Level 2 as recommended in the Centers for Disease Control/National Institutes of Health Manual Biosafety in Microbiological Laboratories. The human blood donor must have tested negative for Hepatitis B (HBV) and Human Immunodeficiency (HIV) viruses. The blood should be treated like any patient blood in using universal precautions.
1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 7 on Hazards.
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
15/30290736 DC : 0 | BS EN ISO 10993-4 - BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 4: SELECTION OF TESTS FOR INTERACTIONS WITH BLOOD |
EN ISO 10993-4:2017 | Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017) |
BS EN ISO 10993-4:2017 | Biological evaluation of medical devices Selection of tests for interactions with blood |
UNE-EN ISO 10993-4:2018 | Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017) |
I.S. EN ISO 10993-4:2017 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 4: SELECTION OF TESTS FOR INTERACTIONS WITH BLOOD (ISO 10993-4:2017) |
AAMI ISO 10993-4 : 2002 | BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 4: SELECTION OF TESTS FOR INTERACTIONS WITH BLOOD |