• ASTM F 2980 : 2013

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Method for Analysis of Heavy Metals in Glass by Field Portable X-Ray Fluorescence (XRF)

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-11-2014

    Language(s):  English

    Published date:  15-02-2013

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 10.04, 2017 Defines field portable X-ray fluorescence (XRF) spectrometric procedures for analyses of arsenic and lead in glass compositions using field portable energy dispersive XRF spectrometers.

    Scope - (Show below) - (Hide below)

    1.1This test method covers field portable X-ray fluorescence (XRF) spectrometric procedures for analyses of arsenic and lead in glass compositions using field portable energy dispersive XRF spectrometers.

    1.2The mass fraction range of arsenic within which this test method is quantitative is given in Table 1. Scope limits were determined from the interlaboratory study results using the approach given in Practice E1601.

    1.3The mass fraction range for which lead was tested is given in Table 1. However, lead results cannot be considered quantitative on the basis of single-sample results because the precision performance is not good enough to allow laboratories to compare results in a quantitative manner.

    Note 1The performance of this test method was evaluated using results based on single-sample determinations from specimens composed of glass beads. One laboratory has determined that performance can be significantly improved by basing reported results on the mean of determinations from multiple samples to overcome inherent heterogeneity of elements in glass beads, especially the element lead. Additional information is provided in Section 17 on Precision and Bias.

    1.3.1To obtain quantitative performance, lead results must consist of the average of four or more determinations.

    1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 7 on Hazards.

    General Product Information - (Show below) - (Hide below)

    Committee F 40
    Document Type Test Method
    Product Note Reconfirmed 2013
    Publisher American Society for Testing and Materials
    Status Superseded

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
    ASTM E 1601 : 2012 : REDLINE Standard Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method
    ASTM E 1621 : 2013 : REDLINE Standard Guide for Elemental Analysis by Wavelength Dispersive X-Ray Fluorescence Spectrometry
    ANSI N43.2 : 2001(R2010) RADIATION SAFETY FOR X-RAY DIFFRACTION AND FLUORESCENCE ANALYSIS EQUIPMENT
    ASTM D 75/D75M : 2014 : REDLINE Standard Practice for Sampling Aggregates
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective