ASTM F 3276 : 2019

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device

Available format(s)

Hardcopy , PDF

Superseded date

22-01-2022

Superseded by

ASTM F 3276 : 2022

Language(s)

English

Published date

06-03-2019

€74.48
Excluding VAT

1.1 This guide describes methods for characterizing the efficacy, under prescribed laboratory conditions, of a brush part designed to clean the external surface of a medical device.

Committee
F 04
DocumentType
Guide
Pages
11
ProductNote
THIS STANDARD ALSO REFERS TO F3208,FDA Guidance,
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This guide describes methods for characterizing the efficacy, under prescribed laboratory conditions, of a brush part designed to clean the external surface of a medical device. The method utilizes force testers to mechanically actuate a brush part across a surface at a constant rate and constant pressure. In the first method, the force required to actuate across the surface is measured. In the next method, which utilizes the same force testers and protocol (actuation motion), the brush part is actuated on a soiled surface and the amount of soil removed is measured, as another indicator of performance.

1.2Brushes designed to clean medical devices after clinical use play an important role in the effective reprocessing of those medical devices.

1.3Inclusions:

1.3.1This guide describes objective, quantifiable, and reproducible methods for evaluating the cleaning characteristics of a brush part, under prescribed laboratory conditions, with a test method that simulates the cleaning challenge of a defined target area(s) of a medical device. This also makes it possible to compare one brush part design to another.

1.3.2By use of this guide, manufacturers of cleaning brushes will be able to evaluate and characterize the cleaning performance of their brushes for the target area(s) of medical device(s) and evaluate modifications to design and construction that might improve performance.

1.3.3By use of this guide, this information can also be shared with the users of the brushes (medical device reprocessors) to help them evaluate the performance of commercially available brushes.

1.4Exclusions:

1.4.1This guide does not assess potential damage that may be inflicted by the brush, or degradation of the brush that may occur during repeated use. Brushes with rigid bristles (e.g., stainless steel or other metals) are predicted to be more likely to damage medical devices than brushes with flexible bristles (e.g., nylon); damage from rigid-bristled brushes should be assessed. Assessing repeated use would require a greatly increased number of test repetitions than what is described in this guide.

1.4.2This guide does not specify acceptance criteria, and the results will be dependent on the specific parameters that are tested (e.g., test soil, drying time, surface area, and materials, etc.) that are tested.

1.4.3This guide is not intended to constitute all steps required to conduct validation of cleaning instructions for a medical device, including use of brushes for this purpose, but provides methods that may be part of a broader protocol to conduct a complete cleaning instructions validation. Separate medical device cleaning instruction validation studies must be conducted.

1.5Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM F 3487 : 2020 Standard Guide for Assessing the Service Life of a Brush Part Intended to Clean a Medical Device

ASTM F 3208 : 2017 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices
ASTM F 3208 : 2019 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices
ASTM F 3208 : 2018 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.