1.1This practice provides guidance for non-destructive photographic analysis of spinal implants prior to, during, and after testing. The purpose of this practice is to provide methods for documenting notable changes in implant characteristics (e.g., surface defects, cracks, plastic deformation) that have occurred during the course of a mechanical test. Documenting these changes may assist in understanding if mechanical failure has occurred, and how.
1.2This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F 2706 : 2008 | Standard Test Methods for Occipital-Cervical and Occipital-Cervical-Thoracic Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1582 : 1998 : R2016 | Standard Terminology Relating to Spinal Implants |
ASTM F 2193 : 2018 : REV A | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 2193 : 2020 | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 1717 : 2021 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2267 : 2004 | Standard Test Method for Measuring Load Induced Subsidence of an Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 2077 : 2003 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 2789 : 2010 : R2015 | Standard Guide for Mechanical and Functional Characterization of Nucleus Devices |
ASTM F 1798 : 2021 | Standard Test Method for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
ASTM F 2193 : 2018 | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 2624 : 2012 | Standard Test Method for Static, Dynamic, and Wear Assessment of Extra-Discal Single Level Spinal Constructs |
ASTM F 2077 : 2022 | Standard Test Methods for Intervertebral Body Fusion Devices |
ASTM F 2423 : 2005 | Standard Guide for Functional, Kinematic, and Wear Assessment of Total Disc Prostheses |
ASTM F 2790:2010 | Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses |
ASTM F 1717 : 2018 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1582 : 1998 : R2003 | Standard Terminology Relating to Spinal Implants |
ASTM F 1717 : 2014 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1798 : 1997 : R2008 | Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
ASTM F 1717 : 2015 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1717 : 2013 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2077 : 2017 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 1717 : 2001 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2267 : 2004 : R2011 | Standard Test Method for Measuring Load Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 2267 : 2003 | Standard Test Method for Measuring Load Induced Subsidence of an Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 2346 : 2018 | Standard Test Methods for Static and Dynamic Characterization of Spinal Artificial Discs |
ASTM F 1717 : 2010 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2624 : 2007 | Standard Test Method for Static, Dynamic, and Wear Assessment of Extra-Discal Spinal Motion Preserving Implants |
ASTM F 2077 : 2000 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 2790 : 2010 : R2014 | Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses |
ASTM F 2346 : 2005 : R2011 | Standard Test Methods for Static and Dynamic Characterization of Spinal Artificial Discs |
ASTM F 1717 : 2004 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2694 : 2007 : R2013 | Standard Practice for Functional and Wear Evaluation of Motion-Preserving Lumbar Total Facet Prostheses |
ASTM F 2077 : 2018 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 2423 : 2011 | Standard Guide for Functional, Kinematic, and Wear Assessment of Total Disc Prostheses |
ASTM F 2193 : 2002 | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 2077 : 2001 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 2789 : 2010 : R2020 | Standard Guide for Mechanical and Functional Characterization of Nucleus Devices |
ASTM F 2706 : 2017 | Standard Test Methods for Occipital-Cervical and Occipital-Cervical-Thoracic Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2624 : 2012 : R2016 | Standard Test Method for Static, Dynamic, and Wear Assessment of Extra-Discal Single Level Spinal Constructs |
ASTM F 2694 : 2016 | Standard Practice for Functional and Wear Evaluation of Motion-Preserving Lumbar Total Facet Prostheses |
ASTM F 1717 : 2011 : REV A | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2077 : 2011 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 1798 : 2013 | Standard Test Method for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
ASTM F 2790 : 2010 : R2019 : EDT 1 | Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses |
ASTM F 2423 : 2011 : R2016 | Standard Guide for Functional, Kinematic, and Wear Assessment of Total Disc Prostheses |
ASTM F 1582 : 1998 : R2011 | Standard Terminology Relating to Spinal Implants |
ASTM F 1717 : 1996 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1798 : 1997 : R2003 | Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
ASTM F 2267 : 2024 | Standard Test Method for Measuring Load-Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 1717 : 2012 : REV A | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2694 : 2007 | Standard Practice for Functional and Wear Evaluation of Motion-Preserving Lumbar Total Facet Prostheses |
ASTM F 2706 : 2008 : R2014 | Standard Test Methods for Occipital-Cervical and Occipital-Cervical-Thoracic Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2193 : 2014 | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 1717 : 2012 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 2193 : 2002 : R2007 | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM F 2789 : 201 | Standard Guide for Mechanical and Functional Characterization of Nucleus Devices |
ASTM F 2346 : 2005 | Standard Test Methods for Static and Dynamic Characterization of Spinal Artificial Discs |
ASTM F 1798 : 1997 | Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants |
ASTM F 1717 : 2009 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model |
ASTM F 1582 : 1998 | Standard Terminology Relating to Spinal Implants |
ASTM F 2077 : 2014 | Test Methods For Intervertebral Body Fusion Devices |
ASTM F 2267 : 2022 | Standard Test Method for Measuring Load-Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 2267 : 2004 : R2018 | Standard Test Method for Measuring Load Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.