• There are no items in your cart

ASTM F 382 : 2017 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Specification and Test Method for Metallic Bone Plates

Available format(s)

PDF

Superseded date

09-09-2024

Language(s)

English

Published date

01-09-2017

€74.48
Excluding VAT

CONTAINED IN VOL. 13.01, 2017 Gives a comprehensive reference for bone plates used in the surgical internal fixation of the skeletal system.

Committee
F 04
DevelopmentNote
Supersedes ASTM F 786 (12/2001)
DocumentType
Redline
Pages
12
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This specification and test method is intended to provide a comprehensive reference for bone plates used in the surgical internal fixation of the skeletal system. The standard establishes consistent methods to classify and define the geometric and performance characteristics of bone plates. The standard also presents a catalog of standard specifications that specify material; labeling and handling requirements; and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of bone plates.

1.2It is not the intention of the standard to define levels of performance or case-specific clinical performance for bone plates, as insufficient knowledge is available to predict the consequences or their use in individual patients for specific activities of daily living. Futhermore, it is not the intention of the standard to describe or specify specific designs for bone plates used in the surgical internal fixation of the skeletal system.

1.3This document may not be appropriate for all types of bone plates. The user is cautioned to consider the appropriateness of the standard in view of a particular bone plate and its potential application.

1.4This document includes the following test methods used in determining the following bone plate mechanical performance characteristics:

1.4.1Standard Test Method for Single Cycle Bend Testing of Metallic Bone Plates—Annex A1, and

1.4.2Standard Test Method for Determining the Bending Fatigue Properties Of Metallic Bone Plates—Annex A2.

1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6Multiple test methods are included in this standard. However, it must be noted that the user is not obligated to test using all of the described methods. Instead, the user should only select test methods that are appropriate for a particular device design. In most instances, only a subset of the herein described test methods will be required.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

FIG. 1Bone Plate Cross-sections

Bone Plate Cross-sectionsBone Plate Cross-sections

1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM F 564 : 2017 : REDLINE Standard Specification and Test Methods for Metallic Bone Staples
ASTM F 2502 : 2017 : REDLINE Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants
ASTM F 897:2002 Standard Test Method for Measuring Fretting Corrosion of Osteosynthesis Plates and Screws
ASTM F 897 : 2002 : R2013 Standard Test Method for Measuring Fretting Corrosion of Osteosynthesis Plates and Screws
ASTM F 897 : 2002 : R2007 Standard Test Method for Measuring Fretting Corrosion of Osteosynthesis Plates and Screws
ASTM F 384 : 2017 : REDLINE Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices

ASTM E 122 : 2017 : REDLINE Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process
ASTM F 565 : 2004 : R2009 Standard Practice for Care and Handling of Orthopedic Implants and Instruments
ASTM F 2503 : 2013 : REDLINE Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
ISO 14602:2010 Non-active surgical implants — Implants for osteosynthesis — Particular requirements

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.