ASTM F 564 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification and Test Methods for Metallic Bone Staples
Hardcopy , PDF
12-12-2024
English
01-09-2017
This specification covers characterization of the design and mechanical function of metallic staples used in the internal fixation of the musculoskeletal system.
Committee |
F 04
|
DocumentType |
Standard
|
Pages |
13
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers characterization of the design and mechanical function of metallic staples used in the internal fixation of the musculoskeletal system. It is not the intention of this specification to describe or specify specific designs for metallic bone staples.
1.2This specification includes the following four test methods for measuring mechanical properties of metallic bone staples:
1.2.1Test Method for Constant Amplitude Bending Fatigue Tests of Metallic Bone Staples—Annex A1.
1.2.2Test Method for Pull-Out Fixation Strength of Metallic Bone Staples—Annex A2.
1.2.3Test Method for Soft Tissue Fixation Strength of Metallic Bone Staples—Annex A3.
1.2.4Test Method for Elastic Static Bending of Metallic Bone Staples—Annex A4.
1.3The values stated in SI units are to be regarded as standard. Any other units of measurement included in this standard are shown for reference only.
1.4Multiple test methods are included in this standard. However, the user is not necessarily obligated to test using all of the described methods. Instead, the user should only select, with justification, test methods that are appropriate for a particular device design. This may be only a subset of the herein described test methods.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM F 2503 : 2008 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2503 : 2023 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 601 : 1998 | Standard Practice for Fluorescent Penetrant Inspection of Metallic Surgical Implants |
ASTM F 75 : 2023 | Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075) |
ASTM F 2503 : 2005 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 601 : 2023 | Standard Practice for Fluorescent Penetrant Inspection of Metallic Surgical Implants |
ASTM F 629 : 2024 | Standard Practice for Radiography of Cast Metallic Surgical Implants |
ASTM F 75 : 2018 | Standard Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Castings and Casting Alloy for Surgical Implants (UNS R30075) |
ASTM F 2503 : 2023 : EDT 1 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 629 : 2020 | Standard Practice for Radiography of Cast Metallic Surgical Implants |
ASTM F 86 : 2013 | Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants |
ASTM F 2503 : 2013 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM E 122 : 2017 : R2022 | Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process |
ASTM E 122 : 2017 | Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process |
ASTM F 601 : 2018 | Standard Practice for Fluorescent Penetrant Inspection of Metallic Surgical Implants |
ASTM F 2503 : 2020 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 382 : 2017 | Standard Specification and Test Method for Metallic Bone Plates |
ASTM F 382 : 2024 | Standard Specification and Test Method for Metallic Bone Plates |
ASTM F 565 : 2021 | Standard Practice for Care and Handling of Orthopedic Implants and Instruments |
ASTM E 4 : 2021 | Standard Practices for Force Calibration and Verification of Testing Machines |
ASTM E 467 : 2008 : R2014 | Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System |
ASTM F 86 : 2021 | Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants |
ASTM F 629 : 2024 | Standard Practice for Radiography of Cast Metallic Surgical Implants |
ASTM F 565 : 2004 : R2018 | Standard Practice for Care and Handling of Orthopedic Implants and Instruments |
ASTM E 467 : 2021 | Standard Practice for Verification of Constant Amplitude Dynamic Forces in an Axial Fatigue Testing System |
ASTM E 4 : 2024 | Standard Practices for Force Calibration and Verification of Testing Machines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.