ASTM F 623 : 1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Performance Specification for Foley Catheter

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-10-1999

€67.30
Excluding VAT

CONTAINED IN VOL. 13.01, 2015 Defines performance requirements for the short-term utilization of a single-use, balloon-retention catheter, French sizes 12 through 26 inclusive, used by the medical professions for providing a means of bladder drainage by means of the urethra.

Committee
F 04
DocumentType
Standard
Pages
8
ProductNote
Reconfirmed 1999
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 This specification establishes performance requirements for the short-term utilization of a single-use, balloon-retention catheter, French sizes 12 through 26 inclusive, used by the medical professions for providing a means of bladder drainage by means of the urethra. The product is manufactured in various sizes and materials such as latex, silicone, rubber, and various polymers (as well as combinations of these) and is provided nonsterile for sterilization and sterile for single use only. Catheters whose surface has been chemically treated to effect biocompatibility or microbial properties may be tested to this specification.

1.2 Exclusions—Long-term indwelling usage (over 30 days) is encountered with this product, but not commonly, and is therefore considered an exception to this specification. Similarly, the use of such catheters for nonurethral catheterization (such as for nephrostomy, suprapubic cystostomy, ureterostomy, gastrostomy, enemas, and so forth) is excluded from the scope of this specification. Likewise, three lumen catheters, 30-cm3 balloon and pediatric catheters, and catheters whose surface has been chemically treated to enhance their lubricity have not been tested to this specification and excluded from the scope of this specification and will require separate standard development.

1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F 748 : 2016 : REDLINE Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.