ASTM F 949 : 2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Poly(Vinyl Chloride) (PVC) Corrugated Sewer Pipe With a Smooth Interior and Fittings
Hardcopy , PDF
23-09-2019
English
01-04-2015
This specification covers requirements, test methods, and materials for 4 to 48 in. diameter poly(vinyl chloride) (PVC) corrugated pipe with a smooth interior.
Committee |
F 17
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers requirements, test methods, and materials for 4 to 48 in. diameter poly(vinyl chloride) (PVC) corrugated pipe with a smooth interior. This profile wall pipe consists of an outer corrugated wall fused to a smooth inner wall providing pipe stiffness levels of 46 psi and 115psi. Joints and fittings are included in this specification.
1.2The requirements of this specification are intended to provide pipe and fittings suitable for underground use in nonpressure applications for sanitary sewers, storm sewers, and perforated and unperforated pipes for subdrainage.
Note 1:Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.
1.3Pipe and fittings produced to this specification shall be installed in accordance with Practice D2321.
Note 2:For perforated pipe applications, the size of the embedment zone and permeability of the embedment material are important to the system's ability to provide the desired level of infiltration or exfiltration. The gradation of the embedment material must be compatible with the perforation slot size to avoid backfill migration into the pipe.
1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5The following precautionary caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 1600 : 1999 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM F 1057 : 2019 | Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique |
ASTM D 2321 : 2005 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 2321 : 2009 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 2152 : 1995 : R2010 | Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion |
ASTM D 2321 : 2014 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 3034 : 2006 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM F 1057 : 1987 : R2005 | Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique |
ASTM D 2122 : 1998 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 2564 : 2004 : R2009 : EDT 1 | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2564 : 2004 : EDT 1 | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2564 : 2012 | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2444 : 1999 : R2010 | Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) |
ASTM D 2152 : 1995 : R2003 | Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion |
ASTM D 1784 : 1999 : REV A : EDT 1 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 3212 : 1996 : REV A : R2003 | Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
ASTM D 2444 : 2017 | Standard Practice for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) |
ASTM D 2412 : 2011 | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 2412 : 2002 : R2008 | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 2152 : 2013 | Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion |
ASTM D 1784 : 2003 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 2321 : 2011 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 2412 : 2010 : REV A | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 3034 : 2014 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 2321 : 2000 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM F 1057 : 1987 : R2000 | Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique |
ASTM D 1600 : 2007 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 1784 : 2011 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 3034 : 2004 : REV A | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 1600 : 2013 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 3212 : 2007 : R2013 | Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
ASTM D 1600 : 2014 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 1784 : 2008 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 1600 : 2008 | Standard Terminology for Abbreviated Terms Relating to Plastics |
ASTM D 2321 : 2004 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 2412 : 1996 : REV A | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 3212 : 2007 | Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
ASTM D 2855 : 1996 : R2010 | Standard Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings |
ASTM D 2412 : 2002 | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 2122 : 1998 : EDT 1 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 2321 : 2014 : EDT 1 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 2321 : 1974 | Recommended Practice for Underground Installation Of Flexible Thermoplastic Sewer Pipe |
ASTM D 2321 : 2004 : EDT 1 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 3212 : 1996 : REV A : R2003 : EDT 1 | Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
ASTM D 3034 : 2015 : EDT 1 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 2855 : 2015 | Standard Practice for the Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets |
ASTM D 2444 : 1999 | Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) |
ASTM D 2564 : 1991 | Standard Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 1784 : 2006 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 1600 : 2018 | Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024) |
ASTM D 3212 : 1996 : REV A | Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals |
ASTM D 2152 : 2017 | Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion |
ASTM D 2855 : 1996 : R2002 | Standard Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings |
ASTM D 1784 : 2007 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 2444 : 1999 : R2005 | Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) |
ASTM D 2321 : 2008 | Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications |
ASTM D 3034 : 2008 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM F 1057 : 2010 | Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique |
ASTM D 2122 : 1998 : R2004 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 3034 : 2014 : REV A | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 2564 : 2002 | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2122 : 2016 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 2564 : 1991 : REV A | Standard Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2564 : 2004 | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 3034 : 2016 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 1784 : 2002 | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 2412 : 2011 : R2018 | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 2122 : 1998 : R2010 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 2855 : 1996 | Standard Practice for Making Solvent-Cemented Joints with Poly(Vinyl Chloride) (PVC) Pipe and Fittings |
ASTM D 2564 : 1996 : REV A | Standard Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems |
ASTM D 2152 : 1995 | Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion |
ASTM D 1784 : 2006 : REV A | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
ASTM D 2412 : 2010 | Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading |
ASTM D 3034 : 2004 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM F 1057 : 2017 | Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique |
ASTM D 2122 : 2015 | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 3034 : 2000 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
ASTM D 3034 : 2015 | Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.