• Shopping Cart
    There are no items in your cart

ASTM G 207 : 2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Indoor Transfer of Calibration from Reference to Field Pyranometers

Available format(s)

Hardcopy , PDF

Superseded date

15-07-2019

Language(s)

English

Published date

01-07-2011

€67.30
Excluding VAT

CONTAINED IN VOL. 14.04, 2015 Specifies methods applicable to the indoor transfer of calibration from reference to field radiometers to be used for measuring and monitoring outdoor radiant exposure levels.

Committee
G 03
DocumentType
Test Method
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 The method described in this standard applies to the indoor transfer of calibration from reference to field radiometers to be used for measuring and monitoring outdoor radiant exposure levels.

1.2 This test method is applicable to field radiometers regardless of the radiation receptor employed, but is limited to radiometers having approximately 180° (2π Steradian), field angles.

1.3 The calibration covered by this test method employs the use of artificial light sources (lamps).

1.4 Calibrations of field radiometers are performed with sensors horizontal (at 0° tilt from the horizontal to the earth). The essential requirement is that the reference radiometer shall have been calibrated at horizontal tilt as employed in the transfer of calibration.

1.5 The primary reference instrument shall not be used as a field instrument and its exposure to sunlight shall be limited to outdoor calibration or intercomparisons.

Note 1—At a laboratory where calibrations are performed regularly it is advisable to maintain a group of two or three reference radiometers that are included in every calibration. These serve as controls to detect any instability or irregularity in the standard reference instrument.

1.6 Reference standard instruments shall be stored in a manner as to not degrade their calibration.

1.7 The method of calibration specified for total solar pyranometers shall be traceable to the World Radiometric Reference (WRR) through the calibration methods of the reference standard instruments (Method and Test Method ), and the method of calibration specified for narrow- and broad-band ultraviolet radiometers shall be traceable to the National Institute of Standards and Technology (NIST), or other internationally recognized national standards laboratories (Standard ).

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM G 214 : 2016 : REDLINE Standard Test Method for Integration of Digital Spectral Data for Weathering and Durability Applications

ASTM E 816 : 2015 : REDLINE Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
ASTM E 772 : 2015 : REDLINE Standard Terminology of Solar Energy Conversion
ASTM E 824 : 2011-01 TEST METHOD FOR TRANSFER OF CALIBRATION FROM REFERENCE TO FIELD RADIOMETERS
ISO 9847:1992 Solar energy — Calibration of field pyranometers by comparison to a reference pyranometer
ASTM G 138 : 2012 : REDLINE Standard Test Method for Calibration of a Spectroradiometer Using a Standard Source of Irradiance
ASTM G 167 : 2015 : REDLINE Standard Test Method for Calibration of a Pyranometer Using a Pyrheliometer
ASTM G 113 : 2016 : REDLINE Standard Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.