BIS IS/IEC 62271-200 : 2003
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UPTO AND INCLUDING 52 KV
17-11-2023
12-01-2013
NATIONAL FOREWORD
1. General
2. Normal and special service conditions
3. Terms and definitions
4. Ratings
5. Design and construction
6. Type tests
7. Routine tests
8. Guide to the selection of metal-enclosed
switchgear and controlgear for service
9. Information to be given with enquiries,
tenders and orders
10. Rules for transport, storage, installation,
operation and maintenance
11. Safety
Annex A (normative) - Internal fault - Method for
testing the metal-enclosed switchgear and
controlgear under conditions of arcing due
to an internal fault
Annex B (normative) - Partial discharge measurement
Annex C (informative) - Explanatory notes
Bibliography
Describes requirements for factory-assembled metal-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor and outdoor installation, and for service frequencies up to and including 60 Hz.
DevelopmentNote |
Issue Date: 01/09/2008. (02/2009)
|
DocumentType |
Standard
|
PublisherName |
Bureau of Indian Standards
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 62271-200:2011 | Identical |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
BIS IS 12063 : 1987(R2004) | CLASSIFICATION OF DEGREES OF PROTECTION PROVIDED BY ENCLOSURES OF ELECTRICAL EQUIPMENT |
BIS IS 1885-74 : 2012(R2017) | ELECTROTECHNICAL VOCABULARY - PART 74: ELECTRICAL AND MAGNETIC DEVICES |
BIS IS 14659 : 1999(R2004) | A.C. INSULATION-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 38 KV |
BIS IS 6209 : 1982(R2006) | METHODS FOR PARTIAL DISCHARGE MEASUREMENTS |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
BIS IS 2071-1 : 2016 | HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS |
IEC 62271-105:2012 | High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60909-0:2016 | Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents |
BIS IS/IEC 60470 : 2000 | HIGH-VOLTAGE SWITCHGEAR ALTERNATING CURRENT CONTACTORS AND CONTACTOR-BASED MOTOR STARTERS |
IEC 60470:1999 | High-voltage alternating current contactors and contactor-based motor-starters |
BIS IS/ISO/IEC GUIDE 51 : 2005 | GUIDELINES FOR THE INCLUSION OF SAFETY ASPECTS IN STANDARDS |
IEC 60517:1990 | Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60137:2017 | Insulated bushings for alternating voltages above 1000 V |
BIS IS 13234 : 1992(R2017) | GUIDE FOR SHORT-CIRCUIT CURRENT CALCULATION IN THREE-PHASE A.C. SYSTEMS |
BIS IS 1885-17 : 1979(R2017) | ELECTROTECHNICAL VOCABULARY - PART 17: SWITCHGEAR AND CONTROLGEAR |
BIS IS 2584 : 1963(R2001) | METHOD OF TEST FOR ELECTRIC STRENGTH OF SOLID INSULATING MATERIALS AT POWER FREQUENCIES |
IEEE C37.20.7-2007 REDLINE | IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults |
BIS IS 12729 : 2004 | COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
BIS IS/IEC 62271-102 : 2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 50187 : 96 AC 96 | GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.