BS 137-1:1982

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V Methods of test

Available format(s)

Hardcopy , PDF

Superseded date

15-12-1995

Language(s)

English

Published date

31-05-1982

Foreword
Cooperating organizations
Methods of test
Section one. General
1 Scope
2 References
3 Definitions
4 Classification
5 Values of voltage
6 Values which characterize a string insulator unit or
    a rigid insulator
7 Values which characterize an insulator string or an
    insulator set
8 Marking
Section two. General requirements for tests
9 General requirements for electrical tests
10 Lightning impulse voltage tests
11 Switching impulse voltage tests
12 Wet power-frequency voltage tests
13 Wet tests
14 Standard atmospheric conditions for tests
15 Correction factors for atmospheric conditions
16 Classification of tests
Section three. Tests in group I (type tests)
17 General
18 Methods of mounting
19 Time intervals between consecutive applications of
    the voltage
20 Dry lightning impulse withstand voltage test
21 Wet switching impulse withstand voltage test
22 Wet power-frequency withstand voltage test
Section four. Tests in group II (sample tests)
23 General
24 Verification of dimensions
25 Temperature cycle test
26 Electromechanical failing load test (on type B
    string insulator units only)
27 Mechanical failing load test
28 Thermal shock test (for toughened glass insulators
    only)
29 Power-frequency puncture test (for type B insulators
    only)
30 Porosity test (for ceramic insulators only)
31 Galvanizing tests
32 Re-test procedure
Section five. Tests in group III (routine tests)
33 General
34 Visual examination
35 Mechanical routine test
36 Electrical routine test (only on type B insulators
    of ceramic material)
37 Thermal shock routine test (for toughened glass
    parts only)
Figures
1 Temperature correction factor alpha for resistivity
    of water as used in wet tests, where rho20 and rhot
    indicate resistivity at 20 deg C and t deg C
2 Corrections for air density: exponent m versus
    insulating distance d
3 Corrections for humidity: factor kh versus absolute
    humidity
4 Section through very large insulators indicating the
    greatest thickness phi of the insulator

Specifies tests for insulators of ceramic material or toughened glass for use on a.c. overhead power and traction lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.

Committee
PEL/36
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
IEC 60383:1983 Similar to

BS 3288-2:1977 Specification for insulator and conductor fittings for overhead power lines. Dimensions
BS 923-1:1980 Guide on high-voltage testing techniques General
BS 923-2:1980 Guide on high-voltage testing techniques Test procedures
BS 137-2:1973 Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V Requirements
BS 5411-1(1980) : 1980 AMD 8494 METHODS OF TEST FOR METALLIC AND RELATED COATINGS - DEFINITIONS AND CONVENTIONS CONCERNING THE MEASUREMENT OF THICKNESS
BS 3297-1:1982 Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Methods of test

View more information
€227.28
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.