BS 171-4:1978

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power transformers Specification for tappings and connections

Available format(s)

Hardcopy , PDF

Superseded date

23-07-2013

Language(s)

English

Published date

31-08-1978

€231.38
Excluding VAT

National foreword
Cooperating organizations
Section one - Tappings
Clause
1 Scope
2 Requirements valid for all categories of voltage
     variation
2.1 General
2.2 Principal tapping
2.3 Specification of the tapping range
2.4 Short-circuit impedance specification
2.5 Load loss requirements
2.6 Requirements related to temperature rise
     (guarantees and tests)
2.7 Requirements related to operation at a voltage
     higher than the tapping voltage
3 Definition and additional requirements for constant
     flux voltage variation
3.1 Definition of constant flux voltage variation
     (C.F.V.V.)
3.2 Additional requirements for constant flux voltage
     variation (C.F.V.V.)
3.3 Separate winding transformers of rated power up to
     and including 3 150 kVA and a tapping range up to
     and including + or - 5%
4 Definition and additional requirements for variable
     flux voltage variation
4.1 Definition of variable flux voltage variation
     (V.F.V.V.)
4.2 Additional requirements for variable flux voltage
     variation (V.F.V.V.)
5 Definition and additional requirements for combined
     voltage variation
5.1 Definition of combined voltage variation (Cb.V.V.)
5.2 Additional requirements for combined voltage
     variation (Cb.V.V.)
Section two - Connections
6 Connections of phase windings
7 Phase displacement between windings
Appendix A Examples of specifications for transformers
            with tappings
Appendix B Transformer connections in general use
Figures

Requirements valid for all categories of voltage variation, additional requirements for particular types of voltage variation, connections of phase windings and phase displacement between windings.

Committee
PEL/14
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
UNE 20110:1995 Identical

BS 9720:1989 Specification for custom-built transformers and inductors of assessed quality: generic data and methods of test
BS 5622-1:1979 Guide for insulation co-ordination Terms, definitions, principles and rules
BS 6436:1984 Specification for ground mounted distribution transformers for cable box or unit substation connection
BS 5611:1978 Application guide for on-load tap-changers
BS 7565:1992 Specification for traction transformers and inductors
BS 7452:1991 Specification for separating transformers, autotransformers, variable transformers and reactors
BS 7735:1994 Guide to loading of oil-immersed power transformers
BS 5953-1:1980 Guide on power transformers Application of power transformers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.