• BS 171-4:1978

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Power transformers Specification for tappings and connections

    Available format(s):  Hardcopy, PDF

    Superseded date:  23-07-2013

    Language(s):  English

    Published date:  31-08-1978

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National foreword
    Cooperating organizations
    Section one - Tappings
    Clause
    1 Scope
    2 Requirements valid for all categories of voltage
         variation
    2.1 General
    2.2 Principal tapping
    2.3 Specification of the tapping range
    2.4 Short-circuit impedance specification
    2.5 Load loss requirements
    2.6 Requirements related to temperature rise
         (guarantees and tests)
    2.7 Requirements related to operation at a voltage
         higher than the tapping voltage
    3 Definition and additional requirements for constant
         flux voltage variation
    3.1 Definition of constant flux voltage variation
         (C.F.V.V.)
    3.2 Additional requirements for constant flux voltage
         variation (C.F.V.V.)
    3.3 Separate winding transformers of rated power up to
         and including 3 150 kVA and a tapping range up to
         and including + or - 5%
    4 Definition and additional requirements for variable
         flux voltage variation
    4.1 Definition of variable flux voltage variation
         (V.F.V.V.)
    4.2 Additional requirements for variable flux voltage
         variation (V.F.V.V.)
    5 Definition and additional requirements for combined
         voltage variation
    5.1 Definition of combined voltage variation (Cb.V.V.)
    5.2 Additional requirements for combined voltage
         variation (Cb.V.V.)
    Section two - Connections
    6 Connections of phase windings
    7 Phase displacement between windings
    Appendix A Examples of specifications for transformers
                with tappings
    Appendix B Transformer connections in general use
    Figures

    Abstract - (Show below) - (Hide below)

    Requirements valid for all categories of voltage variation, additional requirements for particular types of voltage variation, connections of phase windings and phase displacement between windings.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/14
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 9720:1989 Specification for custom-built transformers and inductors of assessed quality: generic data and methods of test
    BS 5622-1:1979 Guide for insulation co-ordination Terms, definitions, principles and rules
    BS 6436:1984 Specification for ground mounted distribution transformers for cable box or unit substation connection
    BS 5611:1978 Application guide for on-load tap-changers
    BS 7565:1992 Specification for traction transformers and inductors
    BS 7452:1991 Specification for separating transformers, autotransformers, variable transformers and reactors
    BS 7735:1994 Guide to loading of oil-immersed power transformers
    BS 5953-1:1980 Guide on power transformers Application of power transformers
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective