BS 1756-3:1971

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Methods for the sampling and analysis of flue gases Analysis by the Haldane apparatus

Available format(s)

Hardcopy , PDF

Withdrawn date

01-06-2005

Language(s)

English

Published date

27-10-1971

€231.38
Excluding VAT

Cooperating organizations
Foreword
Method
1. Scope
2. General
3. Components of apparatus
4. Reagents
5. General procedure
6. Assembling the apparatus
7. Checking the apparatus
8. Analysis of the sample
9. Calculation and reporting of results
Figures
1a. General arrangement of the Haldane apparatus
1b. General arrangement of the modified Haldane
     apparatus (for carbon dioxide only)
2. Burette
3. Compensating bulb B
4a. Water jacket C
4b. Air tube D
5a. Potash pipette F
5b. Potash pipette F, alternative design for carbon
     dioxide only
6. Potash reservoir G
7. Pyrogallol pipette H
8. Combustion pipette J
9. Connecting piece N
10. Connecting piece P
11. Sample intake tube T
12. Suitable levelling device for mercury reservoir E
13. Suitable levelling device for potash reservoir G
14. Apparatus for the filtration of chromous chloride
     solution

Apparatus, reagents, method, sample analysis, calculation, reporting of results.

Committee
EH/2
DevelopmentNote
Supersedes 91/57230 DC. (03/2006)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

BS 3156-1:1968 Analysis of fuel gases General analysis
BS 7186:1989 Specification for non-domestic gas-fired overhead radiant tube heaters
BS 845-2:1987 Methods for assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids. Comprehensive procedure
BS 5991:1989 Specification for indirect gas fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirements (2nd family gases)
BS 5990:1990 Specification for direct gas-fired forced convection air heaters with rated heat inputs up to 2 MW for industrial and commercial space heating: safety and performance requirements (excluding electrical requirement) (2nd family gases)
BS 5978-1:1989 Safety and performance of gas-fired hot water boilers (60 kW to 2 MW input) Specification for general requirements
BS 3300:1974 Specification for kerosine (paraffin) unflued space heaters, cooking and boiling appliances for domestic use
BS 5978-1:1983 Safety and performance of gas-fired hot water boilers (60kW to 2 MW input) Specification for general requirements
BS 5809:1980 Specification for safety and efficiency of the gas heating equipment of commercial dishwashing machines
BS 845-1:1987 Methods for assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids Concise procedure
BS 1756-5:1971 Methods for sampling and analysis of flue gases Semi-routine analyses
BS 3300:1985 Specification for paraffin unflued space heating and cooking appliances for domestic use
BS 2049:1985 Specification for paraffin lighting appliances for domestic use
BS 2049:1976 Specification for kerosine (paraffin) lighting appliances for domestic use
BS 3156-5:1969 Analysis of fuel gases Techniques for high pressure gases