Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Preparation of test samples
7 Procedure
8 Calculation
9 Expression of results
10 Precision
11 Test report
Annex A (normative) - Specifications of viscometers
Annex B (normative) - Characteristics of thermometer
Annex C (informative) - Calibration of viscometers
Bibliography

Specifies a method for the determination of the dynamic viscosity of bituminous binders by means of a vacuum capillary viscometer at 60 degrees C in a range between 0,0036 Pa.s to over 580000 Pa.s.