BS 2646-5:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Autoclaves for sterilization in laboratories Methods of test for function and performance
Hardcopy , PDF
26-04-2021
English
15-03-1993
Committees responsible
Foreword
Methods
Section 1. General
1.1 Scope
1.2 References
1.3 Definitions
1.4 Test instruments and gauges
Section 2. Tests for safe function
2.1 Safety valves
2.2 Tests on door interlocks
2.3 Tests on discharge of chamber contents
2.4 Tests on double door autoclaves
Section 3. Tests for performance
3.1 Instrument accuracy, steady state and operating
cycle controls: performance tests
3.2 Liquids sterilization: performance test
3.3 Make-safe: performance tests
3.4 Equipment and glassware sterilization performance
tests
List of references
Describes methods of test used to verify compliance with the requirements for design, construction, safety and performance specified in BS 2646-1:1992.
Committee |
CH/198
|
DevelopmentNote |
Supersedes 91/53016 DC. (06/2005) Reviewed and confirmed by BSI, December 2011. (11/2011)
|
DocumentType |
Standard
|
Pages |
16
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Part of BS2646 describes the methods of test used to verify compliance with the requirements for design, construction, safety and performance specified in BS2646-1:1993.
This standard covers laboratory autoclaves for the sterilization of goods and material which could be infected with organisms categorized as Hazard Group 1,2 or 32). It does not cover autoclaves for use with material infected with organisms in Hazard Group 4, for which complete containment and sterilization of infected condensate is considered to be essential.
This standard does not apply to sterilizers or disinfectors used for medical, dental, pharmaceutical or veterinary purposes which are directly concerned with patient care, or those used for fabrics subjected to sterilization which are required to be dry at the end of the cycle. These are covered by BS3970.
BS 2646-3:1993 | Autoclaves for sterilization in laboratories Guide to safe use and operation |
BS 2646-1:1993 | Autoclaves for sterilization in laboratories Specification for design, construction, safety and performance |
BS 3970-2:1991 | Sterilizing and disinfecting equipment for medical products Specification for steam sterilizers for aqueous fluids in sealed rigid containers |
BS 3970-5:1968 | Sterilizing and disinfecting equipment for medical products Electrically heated steam generators for use with hospital sterilizers |
BS 4937-4:1973 | International thermocouple reference tables Nickel -chromium/nickel - aluminium thermocouples. Type K |
BS 3970-4:1990 | Sterilizing and disinfecting equipment for medical products Specification for transportable steam sterilizers for unwrapped instruments and utensils |
BS 5928:1980 | Specification for bottles for laboratory use |
BS 4937-5(1973) : LATEST | |
BS 5235:1975 | Specification for dial-type expansion thermometers |
BS 6253-1:1982 | Electrical measuring transducers for converting a.c. electrical quantities into d.c. electrical quantities Method for specifying general purpose transducers |
BS 2646-3:1993 | Autoclaves for sterilization in laboratories Guide to safe use and operation |
BS 2646-2:1990 | Autoclaves for sterilization in laboratories Guide to planning and installation |
BS 3970-3:1990 | Sterilizing and disinfecting equipment for medical products Specification for steam sterilizers for wrapped goods and porous loads |
BS 2646-4:1991 | Autoclaves for sterilization in laboratories Guide to maintenance |