BS 2750-6:1980
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Measurement of sound insulation in buildings and of building elements Laboratory measurements of impact sound insulation of floors
Hardcopy , PDF
English
30-06-1980
15-10-1998
National foreword
Cooperating organizations
Method
1. Scope and field of application
2. References
3. Definitions
4. Equipment
5. Test arrangement
6. Test procedure and evaluation
7. Precision
8. Expression of results
9. Test report
Annexes
A. Example of a test procedure
B. Measurement of flanking transmission
Tables
1. Specification for rubber for hammer
2. Correction to sound pressure level readings
Measures impact noise transmissions through floors using a standardized tapping machine. The steady state 1/3 octave band filtered receiving room sound pressure level is measured while the impact sound is tapping on the test floor. Determines the receiving room equivalent absorption area and derives the normalized impact sound pressure level. The results can be used for design and comparison of floors.
| Committee |
EH/1
|
| DocumentType |
Standard
|
| Pages |
14
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| ISO 140-6:1998 | Identical |
| ISO 140-6:1978 | Identical |
| UNE-EN 50629:2016 | Identical |
A newer version of this standard is available.