• Shopping Cart
    There are no items in your cart

BS 2G 238:1996

Current

Current

The latest, up-to-date edition.

Specification for electric cables for general airframe or equipment interconnect use (260°C), nickel plated copper and copper alloy conductors, with wrapped insulation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-01-1996

€198.66
Excluding VAT

Committees responsible
Foreword
Specification
1 Scope
2 References
3 Definitions
4 Classification
5 Construction
6 Designation and marking
7 Packaging and labelling
8 Tests
9 Reference samples
Annex
A (normative) Continuous current ratings
Tables
1 Type 01, class 1: single core interconnect cables
   (260 deg C)
2 Type 02, class 2: single core unscreened airframe
   cables (260 deg C)
3 Type 01, classed 2,3 and 4: multicore unscreened,
   twisted interconnect cables without jacket (260 deg C)
4 Type 02, classes 2,3 and 4: multicore unscreened,
   twisted airframe cables without jacket (260 deg C)
5 Type 03, classes 2, 3 and 4: multicore unscreened,
   twisted interconnect cables with jacket (260 deg C)
6 Type 04, classes 2,3 and 4: multicore unscreened,
   twisted interconnect cables with jacket (260 deg C)
7 Type 05, classes 1,2,3 and 4: single core screened
   with jacket interconnect cable (260 deg C)
8 Type 06, classes 1,2,3 and 4: single core screened
   with jacket, and multicore twisted and screened with
   jacket, airframe cables (260 deg C)
9 Tensile strength and elongation at break of copper
   and copper alloy conductors
10 Tests and requirements for cables types 01 and 02
11 Tests and requirements for cables types 05 and 06
12 Test application
13 Specific test parameters
A.1 Continuous current ratings
Figure
A1. Variation of resistance of copper with temperature
List of references






Committee
ACE/6
DevelopmentNote
Supersedes 93/708471 DC and BS G238(1987) (07/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies the construction and performance requirements for a range of lightweight cables with wrapped insulation and nickel plated conductors suitable for general airframe use and for equipment interconnect use as stated below. The continuous current ratings for the cables are given in Annex A. The following types of cable are specified: It is applicable to cables for use in the following situations. Cables for continuous use where the maximum stabilized conductor temperature does not exceed 260 °C and for applications involving flexing at temperatures down to − 65 °C; Cables for use where the potentials stated below do not exceed 600 V r.m.s and the frequency does not exceed 2 000 Hz: potential between conductors; potential between a conductor and screen; potential between a conductor and the aircraft structure; Interconnect cables for use in areas with some physical protection, such as behind panels or bulkheads. They also have an application for the internal wiring of equipment. Airframe cables of sufficiently robust construction for use for open aircraft wiring. NOTE The latest edition of an Aerospace Series standard is indicated by a prefix number.

DEFSTAN 61-12(PT33)SUPP008/4(2006) : 2006 WIRES, CORDS AND CABLES, ELECTRICAL AIRFRAME WIRES AND CABLES - PART 33: HUMIDITY-RESISTANT - SUPPLEMENT 008: PTFE POLYAMIDE COMPOSITE CABLES RATED AT 260 DEGREES C
DEFSTAN 61-12(PT33)SUPP008/3(2005) : 2005 WIRES, CORDS AND CABLES, ELECTRICAL - PART 33: AIRFRAME WIRES AND CABLES - SUPPLEMENT 008: HUMIDITY-RESISTANT; PTFE POLYAMIDE COMPOSITE CABLES RATED AT 260 DEGREES C
DEFSTAN 61-12(PT33)/5(2005) : 2005 WIRES, CORDS AND CABLES ELECTRICAL - PART 33: AIRFRAME WIRES AND CABLES IN THE TEMPERATURE CATEGORIES OF 135 DEGREES C, 200 DEGREES C AND 260 DEGREES C
DEFSTAN 61-12(PT33)/4(2001) : 2001 AMD 4 2004 WIRES, CORDS AND CABLES, ELECTRICAL - PART 33: AIRFRAME WIRES AND CABLES IN THE TEMPERATURE CATEGORIES OF 135 DEGREES C, 150 DEGREES C, 200 DEGREES C AND 260 DEGREES C - SECTIONAL SPECIFICATION
DEFSTAN 61-12(PT33)/3(2000) : 2000 WIRES, CORDS AND CABLES, ELECTRICAL PART 33: AIRFRAME WIRES AND CABLES IN THE TEMPERATURE CATEGORIES OF 135 DEGREE CENTIGRADE, 150 DEGREE CENTIGRADE, 200 DEGREE CENTIGRADE AND 260 DEGREE CENTIGRADE SECTIONAL SPECIFICATION
DEFSTAN 61-12(PT33)SUPP008/1(2000) : 2000 AMD 3 2004 WIRES, CORDS AND CABLES, ELECTRICAL - PART 33: AIRFRAME WIRES AND CABLES - SUPPLEMENT 008: HUMIDITY-RESISTANT PTFE POLYAMIDE COMPOSITE CABLES RATED AT 260 DEGREES C

BS 2G 231:1990 Specification for conductors for general-purpose aircraft electrical cables and aerospace applications
BS 3G 100-2.3.13:1973 Specification for general requirements for equipment for use in aircraft. All equipment. Environmental conditions Resistance to fire in designated fire zones
BS 3G 229:1993 Schedule for environmental conditions and test procedures for airborne equipment
BS 2G 230:1991 Specification for general requirements for aircraft electrical cables (second series)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.