BS 3041-1:1977
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Radio-frequency connectors Specification for general requirements and measuring methods
Hardcopy , PDF
20-04-2012
English
30-06-1977
Foreword
Cooperating organizations
Chapter 1: General
Clause
1 Scope
2 Object
3 Terminology
4 Classification into groups
5 Electrical ratings
6 Electrical and mechanical requirements
7 Construction
8 Marking
9 IEC type designation
Chapter II: General requirements for tests and measuring
methods
10 Type tests
11 Standard conditions for testing
12 Visual inspection
13 Dimensions
14 Electrical tests
14.1 Reflection coefficient
14.2 Power rating
14.3 Contact resistance
14.4 Variation of contact resistance
14.5 Insulation resistance
14.6 Voltage proof
14.7 Voltage proof (combined with water immersion)
14.8 Screening efficiency
14.9 Capacitance
14.10 R.F. shunt resistance
14.11 Discharge test (corona test)
15 Mechanical tests
15.1 General
15.2 Standard testing sequence
15.3 Insertion and withdrawal force
15.4 Mechanical tests on cable fixing and cable entry
16 Climatic tests
16.1 General
16.2 Climatic sequence
16.3 Damp heat, long term
16.4 Rapid change of temperature
16.5 Sealing
16.6 Mould growth
16.7 Corrosion tests
16.8 Dust
17 Endurance test
Appendix A - Schedule for type tests
Appendix B - Method for measuring the reflection
coefficient of a pair of connectors
Appendix C - Measuring method for r.f. shunt resistance
Provides connectors for r.f. transmission lines for use with electronic equipment to establish uniform requirements for the electrical, climatic and mechanical properties as well as safety aspects, test methods, interchangeability and compatibility both between connectors and between connectors and cables, and classification of connectors into groups according to their ability to withstand extremes of temperature and humidity.
Committee |
EPL/46
|
DevelopmentNote |
Also numbered as IEC 60169-1 Supersedes 76/28826 DC (07/2005)
|
DocumentType |
Standard
|
Pages |
32
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
BS 3041-12:1981 | Radio-frequency connectors Specification for r.f. coaxial connectors with screw coupling, unmatched (type UHF) |
BS QC 222000:1996 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with screw coupling. Characteristic impedance 50 ohms. (Type TNC) |
BS EN 122170:1994 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SSMB |
BS QC 221300:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 3 mm (0,12 in) with snap-on coupling. Characteristic impedance 50 ohms (Type SMB) |
BS QC 221400:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 3 mm (0,12 in) with screw coupling. Characteristic impedance 50 ohms (Type SMC) |
BS 5772-9:1993 | Specification for electromechanical components for electronic equipment: basic testing procedures and measuring methods Miscellaneous tests |
BS 3041-7:1996 | Radio-frequency connectors R.F. coaxial connectors with inner diameter of output conductor 9,5 mm (0,374 in) with bayonet lock. Characteristic impedance 50 ohms (Type C) |
BS QC 221200:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock. Characteristic impedance 50 ohms (Type BNC) |
BS EN 122160:1996 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SSMA |
BS QC 222400:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 5,6 mm (0,22 in). Characteristic impedance 75 ohms (type 1,6/5,6). Characteristic impedance 50 ohms (type 1,8/5,6) with similar mating dimensions |
BS EN 122130:1994 | Harmonized system of quality assessment for electronic components. Sectional specification: radio frequency coaxial connectors. Series SMB |
BS QC 221100:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 4,13 mm (0,163 in) with screw coupling. Characteristic impedance 50 ohms (Type SMA) |
BS QC 222100:1997 | Radio-frequency connectors. RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling. Characteristic impedance 50 ohms (75 ohms) (Type N) |
BS 3041-2:1977 | Radio-frequency connectors Specification for coaxial unmatched connector |
BS EN 122200:1995 | Harmonized system of quality assessment for electronic components. Sectional specification. Radio frequency coaxial connectors. Series TNC |
BS 2011-2.1A:1977 | Environmental testing. Tests Tests A. Cold |
BS 2011-2.1B:1977 | Environmental testing. Tests Tests B. Dry Heat |
BS 2011-2.1Da:1977 | Environmental testing. Tests Test Da. Accelerated damp heat |
BS 2011-2.1U(1977) : LATEST | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - ROBUSTNESS OF TERMINATIONS AND INTEGRAL MOUNTING DEVICES |
BS 2011-2.1Ca:1977 | Environmental testing. Tests Test Ca. Damp heat, steady state |
BS 2011-2.1J:1977 | Environmental testing. Tests Test J. Mould growth |
BS 2011-2.1Fc:1977 | Basic enviromental testing proceedures Tests. Test Fc and guidance: Vibration (sinusoidal) |
BS 2011-2.1T(1977) : LATEST | |
BS 2011-2.1Q:1977 | Basic environmental testing procedure Part 2-17. Tests. Test Q: Sealing |
BS 2011-2.1M(1977) : LATEST | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - LOW AIR PRESSURE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.