• BS 3297-1:1982

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Methods of test

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-12-1995

    Language(s):  English

    Published date:  31-05-1982

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Cooperating organizations
    Methods of test
    Section one. General
    1. Scope
    2. References
    3. Definitions
    4. Values of voltages
    5. Values which characterize a post insulator
    6. Marking
    Section two. General requirements for tests
    7. General requirements for electrical tests
    8. Lightning impulse voltage tests
    9. Switching impulse voltage tests
    10. Power-frequency voltage tests
    11. Wet tests
    12. Standard atmospheric conditions for tests
    13. Correction factors for atmospheric conditions
    14. Classification of tests
    Section three. Tests in group 1 (type tests)
    15. General
    16. General requirements for electrical tests in group 1
    17. Dry lightning impulse withstand voltage test
    18. Dry or wet switching impulse withstand voltage
         test
    19. Dry power-frequency withstand voltage test
         (applicable only to post insulators for indoor use)
    20. Wet power-frequency withstand voltage test
         (applicable only to post insulators for outdoor use)
    21. Tests for mechanical strength
    22. Test for deflection under load
    Section four. Tests in group II (sample tests)
    23. General
    24. Verification of dimensions
    25. Temperature cycle test
    26. Power-frequency puncture test
    27. Porosity test (for ceramic post insulators only)
    28. Galvanizing test
    29. Re-test procedure
    Section five. Test in group III (routine tests)
    30. General
    31. Visual examination
    32. Mechanical routine test
    33. Thermal shock routine test (for toughened glass
         parts only)
    34. Electrical routine test (for type B post insulators
         and for type B units used for composing a type A
         post insulator)
    Appendix
    A. Methods of testing for tolerances of parallelism,
        eccentricity and angular deviation for post
        insulators
    Figures
    1. Temperature correction factor alpha for resistivity
        of water as used in wet tests, where p20 and pt
        indicate resistivity at 20 deg C and t deg C
    2. Corrections for air density. Exponent m versus
        insulating distance d in metres
    3. Humidity corrections for dry lightning impulse and
        dry switching impulse tests Factors k and kh against
        humidity
    4. Humidity correction for dry power-frequency voltage
        test. Factor k against absolute humidity (kh = km
        with m given in figure 2)
    5. Section through very large insulators indicating the
        greatest thickness phi of the insulator
    A.1 Untitled
    A.2 Untitled
    A.3 Untitled

    Abstract - (Show below) - (Hide below)

    Specifies tests for post insulators and insulator units for indoor and outdoor service in electrical installations or equipment operating on alternating current with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/36
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7354:1990 Code of practice for design of high-voltage open-terminal stations
    BS 5463:1977 Specification for a.c. switches of rated voltage above 1 kV
    BS 5253:1975 Specification for a.c. disconnectors (isolators) and earthing switches of rated voltage above 1 kV
    BS 3297-3:1982 Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Guide to insulator practice
    BS 137-1:1982 Insulators of ceramic material or glass for overhead lines with a nominal voltage greater than 1000 V Methods of test

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 923-1:1980 Guide on high-voltage testing techniques General
    BS 923-2:1980 Guide on high-voltage testing techniques Test procedures
    BS 5411-1(1980) : 1980 AMD 8494 METHODS OF TEST FOR METALLIC AND RELATED COATINGS - DEFINITIONS AND CONVENTIONS CONCERNING THE MEASUREMENT OF THICKNESS
    BS 3297-2:1982 Post insulators of ceramic material or glass for nominal voltages greater than 1000 V Specification for dimensions
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective