• BS 4272-3:1989

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Anaesthetic and analgesic machines Specification for continuous flow anaesthetic machines

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  26-09-2012

    Language(s):  English

    Published date:  31-03-1989

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Committees responsible
    Specification
    1 Scope
    2 Definitions
    3 General
    4 Connecting yokes for medical gas cylinders
    5 Connections for piped medical gas supplies
    6 Cylinder and pipeline gauges and indicators
    7 Pressure regulators
    8 Machine gas piping
    9 Machine gas delivery system
    10 Rotary flow control valves
    11 Flowmeters
    12 Gas mixers without monitoring flowmeters for each
        gas
    13 General requirements for vaporizers
    14 Concentration-calibrated vaporizers
    15 Non-calibrated vaporizers
    16 Common gas outlet
    17 Auxiliary gas outlets
    18 Oxygen flush
    19 Oxygen supply failure
    20 Marking and labelling
    21 User instruction manual
    Appendices
    A Recommendations for cleaning and servicing of
        anaesthetic machines
    B Method of test for pressure gauge integrity
    C Method of test for leakage from the machine gas
        piping
    D Method of test for cross-contamination
    E Method of test for leakage from the machine gas
        delivery system
    F Method of test for vaporizer accuracy
    G Method of filling the vaporizer prior to testing for
        liquid discharge
    H Method of test for average delivered concentration
        of anaesthetic vapour from the vaporizer
    Tables
    1 Test torque values for flow control valve knob
    2 Settings to be used for testing vaporizer accuracy
    Figures
    1 Profile of oxygen flow control knob
    2 Auxiliary gas outlet probe for oxygen
    3 Auxiliary gas outlet probe for air
    4 Test apparatus for determining cross-contamination
    5 Test apparatus for determining leakage from the
        machine gas delivery system

    Abstract - (Show below) - (Hide below)

    Basic design and performance requirements.

    General Product Information - (Show below) - (Hide below)

    Committee CH/121/1
    Development Note Supersedes 86/53251 DC and 89/53846 DC (08/2005) Inactive for the new design. (10/2007)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS EN ISO 80601-2-13:2012 Medical electrical equipment Particular requirements for basic safety and essential performance of an anaesthetic workstation
    UNE-EN ISO 80601-2-13:2013 Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011)
    BS EN ISO 80601-2-13:2012+A2:2019 Medical electrical equipment Particular requirements for basic safety and essential performance of an anaesthetic workstation
    EN ISO 80601-2-13:2012 Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation (ISO 80601-2-13:2011)
    I.S. EN ISO 80601-2-13:2012 MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AN ANAESTHETIC WORKSTATION (ISO 80601-2-13:2011)
    UNI EN ISO 80601-2-13 : 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 2-13: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AN ANAESTHETIC WORKSTATION
    ISO 80601-2-13:2011 Medical electrical equipment Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
    BS 5724-2.13(1990) : 1990 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR ANAESTHETIC MACHINES

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 4884-1:1973 Specification for technical manuals Content
    BS 1752:1983 Specification for laboratory sintered or fritted filters including porosity grading
    BS 4196-4:1981 Sound power levels of noise sources Engineering methods for determination of sound power levels for sources in free-field conditions over a reflecting plane
    VDI/VDE 3513 Blatt 2:1978-12 Variable area flowmeters; accuracy
    BS 3849-2:1988 Conical connectors for anaesthetic and respiratory equipment Specification for screw-threaded weight-bearing connectors
    BS 1319C:1976 Colours for the identification of the contents of medical gas cylinders
    BS 4884-2:1974 Specification for technical manuals Presentation
    BS 2099:1989 Specification for castors for hospital equipment
    BS 5724-1:1979 Medical electrical equipment Specification for general safety requirements
    BS 5682:1984 Specification for terminal units, hose assemblies and their connectors for use with medical gas pipeline systems
    BS 3849-1:1988 Conical connectors for anaesthetic and respiratory equipment Specification for cones and sockets (excluding 8.5 mm size)
    BS 1319:1976 Specification for medical gas cylinders, valves and yoke connections
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective