• BS 4553-2:1998

    Current The latest, up-to-date edition.

    Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  29-04-2005

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    1 Scope
    2 Normative references
    3 Definitions
    4 Voltage designation
    5 Phase conductor
    6 Insulation
    7 Identification of phase core
    8 Bedding
    9 Concentric layer
    10 Binders
    11 Oversheath
    12 Cable marking
    13 End sealing
    14 Schedule of tests
    15 Test conditions
    16 Routine tests
    17 Sample tests
    18 Type tests
    Annex A (informative) Recommendations for the selection
            and operation of cables
    Annex B (informative) Recommendations for installations of
            cables
    Annex C (informative) Information to be provided with enquiry
            or order
    Annex D (normative) Measurement of thickness
    Annex E (normative) Voltage tests on completed cables
    Annex F (Spare)
    Annex G (normative) Compatibility test
    Annex H (informative) Notes on type tests
    Annex J (informative) Guide to use
    Bibliography

    Abstract - (Show below) - (Hide below)

    Construction requirements and methods of tests for cables intended for use in fixed installations in industrial areas, buildings and similar applications. For use where current loading gives conductor temperature rise not exceeding 90°C and where maximum short circuit conductor temperature is 250°C.

    Scope - (Show below) - (Hide below)

    This British Standard specifies requirements for construction and gives methods of test for XLPE-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth.

    The cables specified in this part of BS 4553 have a central phase conductor insulated with XLPE and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 90 °C and for a maximum short-circuit conductor temperature of 250 °C.

    NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched.

    NOTE 2 Due to the relatively high conductor temperature, there is a risk of drying out the surrounding soil causing an increase in thermal resistivity which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating temperature should be assumed to take into account the possible effects of soil drying out.

    NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.

    Guidance concerning selection, installation and usage is given in Annex A, Annex B and Annex J respectively.

    General Product Information - (Show below) - (Hide below)

    Committee GEL/20/17
    Development Note Together with BS 4553-1(1998) & BS 4553-3(1998), Supersedes 97/201035 DC & 02/206315 DC (02/2004) Reviewed and confirmed by BSI, January 2012. (12/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 4727-2:GRP08(1994) : 1994 GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES
    BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
    BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
    BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
    IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
    BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods