BS 4553-3:1998

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire

Available format(s)

Hardcopy , PDF

Withdrawn date

31-01-2019

Language(s)

English

Published date

29-04-2005

€156.59
Excluding VAT

Committees responsible
Foreword
1 Scope
2 Normative references
3 Definitions
4 Voltage designation
5 Phase conductor
6 Insulation
7 Identification of phase core
8 Bedding
9 Concentric layer
10 Binders
11 Oversheath
12 Cable marking
13 End sealing
14 Schedule of tests
15 Test conditions
16 Routine tests
17 Sample tests
18 Type tests
Annex A (informative) Recommendations for the selection and
        operation of cables
Annex B (informative) Recommendations for installation of
        cables
Annex C (informative) Information to be provided with
        enquiry or order
Annex D (normative) Measurement of thickness
Annex E (normative) Voltage tests on completed cables
Annex F (Spare)
Annex G (normative) Compatibility test
Annex H (informative) Notes on type tests
Annex J (normative) Guide to use
Bibliography

When assessed by specified tests, these cables produce lower levels of smoke and corrosive products under exposure to fire, compared with corresponding cables conforming to BS 4553-1 and BS 4553-2.

Committee
GEL/20/17
DevelopmentNote
Together with BS 4553-1(1998) & BS 4553-2(1998),it supersedes 97/201035 DC & 02/206302 DC. (02/2004) Reviewed and confirmed by BSI, November 2012. (10/2012)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

This British Standard specifies requirements for construction and describes methods of test for XLPE-insulated single-phase split concentric cables for operation on an earthed neutral system at nominal voltages up to and including 1 000 V between phases and 600 V to earth and which, when assessed by the specified tests, produce lower levels of smoke and corrosive products under exposure to fire, compared with corresponding cables conforming to BS 4553-1 and BS 4553-2. In this standard, the level of corrosive (and acid) gases is determined by measurement of hydrochloric acid (HCl) in accordance with BS EN 50267-2-1 . The cables specified in this part of BS 4553 have a central phase conductor insulated with XLPE and a concentric layer comprising bare copper wires (earth continuity conductor) and copper wires covered with extruded polymer (neutral conductor). The cables are intended for use in fixed installations in industrial areas, buildings and similar applications. They are suitable for use in situations where the combination of ambient temperature and temperature rise due to loading current results in a conductor temperature not exceeding 90 °C and for a maximum short-circuit conductor temperature of 250 °C. NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they may be touched. NOTE 2 Due to the relatively high conductor temperature, there is a risk of drying out the surrounding soil causing an increase in thermal resistivity which in turn would lead to the cable temperature rising to a higher value than anticipated. For cable laid directly in the ground, a suitable de-rating factor should be applied or a lower maximum sustained conductor operating temperature should be assumed to take into account the possible effects of soil drying out. NOTE 3 In installations which include cable joints and terminations, the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable. Guidance concerning selection, installation and usage is given in Annex A, Annex B and Annex J respectively.

PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries

BS 4727-2:GRP08(1994) : 1994 GLOSSARY OF ELECTROTECHNICAL, POWER, TELECOMMUNICATION, ELECTRONICS, LIGHTING AND COLOUR TERMS - TERMS PARTICULAR TO POWER ENGINEERING - ELECTRIC CABLES
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
BS EN 60811-1-3:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Methods for determining the density. Water absorption tests. Shrinkage test
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS 7622-2:1993 Measurement of smoke density of electric cables burning under defined conditions Test procedure and requirements
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
BS EN 60811-1-2:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Thermal ageing methods
BS EN 50266-2-4:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables. Procedures Category C

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.