BS 4856-3:1975
Current
The latest, up-to-date edition.
Methods for testing and rating fan coil units, unit heaters and unit coolers Thermal and volumetric performance for heating and cooling duties; with additional ducting
Hardcopy , PDF
English
30-09-1975
Co-operating organizations
Foreword
Methods
1 Scope
2 References
3 Definitions
4 Operating conditions of units
5 Nomenclature
6 Object of the test method
7 Testing conditions
8 Instrumentation
9 Test equipment
10 Test facility
11 Air temperature measurement
12 Test method
13 Test method (air side measurements)
14 Calculations
15 Rating tests
16 Example
17 Sensible and latent cooling rating tests
18 Enclosure sweating tests and condensate disposal
tests
Appendix
A Heating units with fan installed downstream of
the coil
Tables
1 Steady state conditions
2 Rating test for steam as primary fluid
3 Rating tests for water or heat transfer fluid
4 Latent cooling rating test series
5 Enclosure sweat test conditions
Figures
1(a) Thermometer pocket for steam test
1(b) Thermometer pocket for hot water test
1(c) Thermometer pocket for use in vertical pipes
over 75 mm diameter
1(d) Thermometer pocket for use in horizontal pipes
over 75 mm diameter
2 Multi-junction differential thermocouple
3(a) Inverted U-tube manometer
3(b) Piezometer ring
4(a) Thermometer shield
4(b) Thermocouple shield
5 Inlet air sampling tube
6 Outlet air sampling tube
7 Steam test equipment
8 Water test equipment
9 Hot water test equipment (maximum water
temperature above 95 deg C)
10(a) Arrangement A of test apparatus
10(b) Arrangement B of test apparatus
11 Temperature and total pressure probe
12 Air flow mixers
13 Inlet temperature measurement
14 Traverse stations
15 Definition of x
16 Pressure-flow characteristics
17 Heat transfer
18 Thermal efficiency
19 Water temperature correction factor heating
20 Water temperature correction factor cooling
21 Graph of Qn versus qar at (tfi - tai) = 60 deg C
22 Graph of Qn versus mf at qar = 0.93 cubic m/s
23(a) Graph of Ra and B versus qar
23(b) Graph of Rwm versus mf
Units for use with additional ducting containing fluid to air heat exchangers and incorporating their own electrically powered fan system. For heating or cooling applications, the latter with or without dehumidification under frost-free conditions.
Committee |
RHE/6
|
DevelopmentNote |
Supersedes 73/34432 DC. (07/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Part of this British Standard deals with methods of carrying out thermal and volumetric tests on units intended for use with additional ducting containing fluid to air heat exchangers and incorporating their own electrically powered fan system. The units may be either for heating or for cooling applications and the latter may be with or without dehumidification under frost-free conditions. The tests are to be carried out on units in an essentially clean condition.
BS 4856-4:1997 | Methods for testing and rating fan coil units, unit heaters and unit coolers Determination of sound power levels of fan coil units, unit heaters and unit coolers using reverberating rooms |
BS 4856-4:1978 | Methods for testing and rating fan coil units, unit heaters and unit coolers Acoustic performance; without additional ducting |
BS 4856-5:1979 | Methods for testing and rating fan coil units, unit heaters and unit coolers Acoustic performance; with ducting |
BS 3763:1976 | The International System of units (SI) |
BS 1042-1:1964 | Measurement of fluid flow in pipes. Orifice plates, nozzles and venturi tubes. |
BS 4194:1967 | Recommendations on the design requirements and testing of controlled-atmosphere laboratories |
BS 1042-2(1964) : LATEST |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.