BS 4954-1:1973

Current

Current

The latest, up-to-date edition.

Methods for testing and rating induction units for air distribution systems Thermal and aerodynamic performance

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

05-10-1973

€217.36
Excluding VAT

Cooperating organizations
Foreword
Methods
1. Scope
2. Definitions
3. Nomenclature
4. Instrumentation
5. Test for total pressure loss of primary air supply
6. Test for the relationship between primary air flow
    rate and nozzle pressure
7. Test for inlet plenum leakage
8. Heat transfer measurements
9. Secondary air flow measurement
10. Interpretation of test results and rating
11. Thermal rating examples
Figures
1. Thermometer pockets in pipes of less than 75 mm
      diameter
2a. Thermometer shield
2b. Thermocouple shield
3. Typical open circuit test equipment
4. Typical closed circuit test equipment
5a. Inverted tube pattern manometer
5b. Piezometer ring
6. Test for total pressure loss of primary air supply
      - typical arrangement
7. Air supply arrangement for leakage test
8a. Location of inlet air temperature measuring
      stations - bounded unit
8b. Location of inlet air temperature measuring
      stations - free standing unit
9. Air flow chamber
10. Determination of air volume flow rate
11. Thermal characteristics
12. Thermal rating example
13a. Water temperature correction factor - heating
13b. Water temperature correction factor - cooling

Specifies methods of test for induction units with water coils for heating and/or sensible cooling duties. It gives instructions for the calculation, interpretation and interpolation of the test results for the thermal and aerodynamic rating of the units.

Committee
RHE/6
DevelopmentNote
Supersedes 71/36147 DC. (07/2005) Reviewed and confirmed by BSI, December 2012. (11/2012)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Current

This British Standard specifies methods of test for induction units with water coils for either (or both) heating and sensible cooling duties. It gives instructions for the calculation, interpretation and interpolation of the test results for the thermal and aerodynamic rating of the units.

NOTE The titles of the British Standards referred to in this Part of this standard are shown on page 26.

BS 4954-2:1978 Methods for testing and rating induction units for air distribution systems Acoustic testing and rating

BS 1041-2.2:1989 Code for temperature measurement. Expansion thermometers Guide to selection and use of dial-type expansion thermometers
BS 1042-1:1964 Measurement of fluid flow in pipes. Orifice plates, nozzles and venturi tubes.
BS 1042-2(1964) : LATEST

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.