• Shopping Cart
    There are no items in your cart

BS 5258-16:1991

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Safety of domestic gas appliances Specification for inset live fuel effect gas fires (2nd and 3rd family gases)

Available format(s)

Hardcopy , PDF

Superseded date

18-12-2002

Superseded by

BS 7977-1:2002

Language(s)

English

Published date

30-09-1991

€271.12
Excluding VAT

Committees responsible
Foreword
Specification
Section 1. General
1 Scope
2 Definitions
3 Classification of appliances
4 General requirements
5 General conditions of test
Section 2. Safety requirements and associated methods
            of test
6 General design and construction
7 Gas soundness
8 Heat input
9 Combustion
10 Ignition
11 Ignition system
12 Flame stability
13 Sooting
14 Flue systems
15 Fire hazard and limiting temperatures
16 Cyclic use test
17 Manual controls
18 Automatic controls
19 Electrical safety
20 User's instructions
21 Installation and servicing
Appendices
A Construction of test box and flue
B Calculation of reference gas heat input
C Determination of clearance flue flow
Figures
1 Illustrations of fuel effect appliances
2 Test box and flue for appliances that can be
    installed in a metal flue box
3 Bubble leak indicator
4 Basic test box
5 Apparatus for the assessment of the products outlet
    design
6 Collecting hood
7 Collecting hood positioning
8 Apparatus for measuring floor and wall temperatures
9 Hearth area for measurement of floor temperature
10 Removable inserts
11 Test box assembly
12 Test flue
13 Sampling probe

Safety requirements and associated methods of test for gas fires of heat input not exceeding 15 kW that are designed to simulate visually solid fuels and to be installed within a builder\'s opening and/or fireplace recess. The appliances may, additionally, be intended for installation in a purpose-designed metal flue box and flue.

Committee
GSE/36
DevelopmentNote
Being considered for approval under the UK Consumer Protection Act 1987, likely approval date Feb 1993.
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

BS 5871-2:1991 Specification for installation of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW (2nd and 3rd family gases)
BS 5482-1:1994 Domestic butane- and propane-gas-burning installations Specification for installations at permanent dwellings
BS 5871-3:1991 Specification for installation of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Decorative fuel effect gas appliances of heat input not exceeding 15 kW (2nd and 3rd family gases)
BS 715:1993 Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW
BS 5871-1:1991 Specification for installation of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Gas fires, convector heaters and fire/back boilers (1st, 2nd and 3rd family gases)
95/717426 DC : DRAFT JAN 1996 SPECIFICATION FOR DOMESTIC GAS FIRED HEATING APPLIANCES - PART 2: COMBINED APPLIANCES - GAS FIRE/BACK BOILER

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 1179-6:1980 Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises
BS 6047-1:1981 Flame supervision devices for domestic, commercial and catering gas appliances Specification for heat sensitive type
BS 5482-1:1979 Domestic butane- and propane-gas-burning installations Installations in permanent dwellings
BS 2871-1:1971 Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation
BS 6448-1:1987 Gas governors Specification for pressure governors with nominal connection size up to 50 mm for gas appliances with inlet pressure up to and including 200 mbar
BS 5482-2:1977 Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings
BS 4550-5:1978 Methods of testing cement Standard sand for concrete cubes

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.