• Shopping Cart
    There are no items in your cart

BS 5258-8:1980

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Safety of domestic gas appliances Combined appliances: gas fire/back boiler

Available format(s)

Hardcopy , PDF

Superseded date

14-05-2003

Language(s)

English

Published date

31-10-1980

€271.12
Excluding VAT

Foreword
Cooperating organizations
Specification
0. Introduction
Section one. General
1. Scope
2. References
3. Definitions
4. Classification of appliances
5. General requirements
6. General conditions of test
Section two. Safety requirements and associated methods
of test
7. General design and construction
8. Soundness
9. Heat input
10. Combustion
11. Ignition
12. Ignition system
13. Flame stability
14. Sooting
15. Flue system
16. Fire hazard and limiting temperatures
17. Prolonged performance test
18. Automatic controls
19. Manual controls
20. Electrical safety
21. User's instructions
22. Installation and servicing
Figures
1. Test box and flue
2. Waterside test rig
3. Bubble leak indicator
4. Spillage detector
5. Apparatus for measuring floor and wall temperatures

Safety requirements and associated test methods for combined boilers (or circulators) and gas fires designed for fitting into or against a fireplace recess and burning 1st, 2nd and 3rd family gases.

Committee
GSE/36
DevelopmentNote
REPLACES BS 1250:PART 1:1966, BS 1250:PART 3:1963 AND BS 2773:1965. Being considered for approval under the UK Consumer Protection Act 1987, likely approval date Aug 1993.
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Superseded
Supersedes

10/30213917 DC : 0 BS 8660-1 - GAS-FIRED MICRO-COGENERATION APPLIANCES OF RATED THERMAL INPUT NOT EXCEEDING 70 KW NET - PART 1: SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF STIRLING ENGINE MICRO-COGENERATION APPLIANCES
BS 5449:1990 Specification for forced circulation hot water central heating systems for domestic premises
BS 5546:2010 Specification for installation and maintenance of gas-fired water-heating appliances of rated input not exceeding 70 kW net
13/30261683 DC : 0 BS 6798 - SPECIFICATION FOR SELECTION, INSTALLATION, INSPECTION, COMMISSIONING, SERVICING AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
08/30166539 DC : DRAFT JULY 2008 BS 6798 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED BOILERS OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 6332-3:1984 Thermal performance of domestic gas appliances Specification for thermal performance of combined appliances: gas fire/back boiler
BS 5546:1990 Specification for installation of gas hot water supplies for domestic purposes (1st, 2nd and 3rd family gases)
BS 5546:2000 Specification for installation of hot water supplies for domestic purposes, using gas-fired appliances of rated input not exceeding 70 kW
BS 5440-1:2000 Installation and maintenance of flues and ventilation for gas appliances of rated heat input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation and maintenance of flues
BS 6798:2009 Specification for installation and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 5482-1:1994 Domestic butane- and propane-gas-burning installations Specification for installations at permanent dwellings
BS 6798:2014 Specification for selection, installation, inspection, commissioning, servicing and maintenance of gas-fired boilers of rated input not exceeding 70 kW net
BS 6798:2000 Specification for installation of gas-fired boilers of rated input not exceeding 70 kW net
BS 6700:1997 Specification for design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages
BS 7977-2:2003 Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler
BS 5871-1:1991 Specification for installation of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Gas fires, convector heaters and fire/back boilers (1st, 2nd and 3rd family gases)
BS 6798:1987 Specification for installation of gas-fired hot water boilers of rated input not exceeding 60 kW
09/30166542 DC : 0 BS 5546 - SPECIFICATION FOR INSTALLATION AND MAINTENANCE OF GAS-FIRED WATER-HEATING APPLIANCES OF RATED INPUT NOT EXCEEDING 70 KW NET
BS 8660-1:2011 Gas-fired micro-cogeneration appliances of rated thermal input not exceeding 70 kW net Specification for selection, installation, inspection, commissioning, servicing and maintenance of Stirling engine micro-cogeneration appliances
BS PAS 33(1999) : 1999 SPECIFICATION FOR THE DESIGN, INSTALLATION AND COMMISSIONING OF GAS FIRED CENTRAL HEATING SYSTEMS IN DOMESTIC PREMISES

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 2871-1:1971 Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation
BS 3554-1:1971 Specification for gas governors Independent governors for inlet pressures up to 25 mbar

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.