• There are no items in your cart

BS 5258-9:1989

Current

Current

The latest, up-to-date edition.

Safety of domestic gas appliances Specification for combined appliances: fanned-circulation ducted-air heaters/circulators

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-10-1989

€254.76
Excluding VAT

Foreword
Committees responsible
Specification
Section one. General
1. Scope
2. Definitions
3. Classification of appliances
4. General requirements
5. General conditions of test
Section two. Safety requirements and associated
methods of test
6. General design and construction
7. Soundness
8. Heat input
9. Combustion
10. Ignition
11. Ignition system
12. Flame stability
13. Sooting
14. Flue system
15. Fire hazard and limiting temperatures
16. Prolonged performance test
17. Manual controls
18. Automatic controls
19. Electrical safety
20. User's instructions
21. Installation and servicing
Appendices
A. Method of test for resistance to airborne lint
B. Apparatus and conditions for combustion tests on
    type C1 appliances
C. Apparatus and conditions for combustion tests on
    type C2 appliances
Figures
1. Test rig: water side
2. Pressure differential criteria to be applied
    according to the height of the appliance air inlet
3. Bubble leak indicator
4. Apparatus for measuring floor and wall temperatures
5. Position of baffle with respect to lint generator
    outlet duct
6. Lint geneator
7. Lint filter
8. Typical test apparatus for type C1 appliances
9. Test apparatus for type C2 appliances

Safety requirements and associated methods of test for heaters either combined with, or designed to be fitted with, circulators. Covers appliances burning 1st, 2nd and 3rd family gases of rated heat inputs of the air heater and circulator not exceeding 60 kW and 8 kW, respectively.

Committee
GSE/20
DevelopmentNote
Supersedes 87/72542 DC. (07/2005) Reviewed and confirmed by BSI, November 2012. (10/2012)
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Current

This Part of BS 5258 specifies safety requirements and describes associated methods of test for gas-fired combined appliances consisting of a fanned-circulation ducted-air heater together with a circulator. The combined appliance is usually of integral construction, the circulator being fitted inside the air heater casing.

It also covers fanned-circulation ducted-air heaters which are designed to be fitted with circulators, as a purchaser’s option.

This Part of this standard only applies to circulators intended for use as an integral part of the combined appliance. Circulators intended for independent use are covered by BS 5258-1.

It covers appliances in which the rated heat input of the air heater does not exceed 60 kW1) and that of the circulator does not exceed 8 kW1).

This Part of BS 5258 is not applicable to:

  1. flueless appliances;
  2. type C appliances burning 3rd family gas;
  3. appliances incorporating full sequence automatic control systems;
  4. appliances with premixed gas and air burners;
  5. appliances designed to make use of the latent heat of condensation of the water vapour in the combustion products.

It does not include the special requirements for appliances for outdoor installation or for appliances with fan-powered combustion circuits or fan-assisted flues.

In specifying requirements for appliances burning 2nd family gases it is assumed that a meter governor will be fitted and for appliances burning 3rd family gases it is assumed that the gas supply from the container will be governed by a pressure regulator complying with the requirements of BS 3016.

There are circumstances, particularly in regard to central heating, where means of control may be provided either on the heating appliance or as part of the installation; where this option exists it is stated. Where the control forms part of the installation and its application conforms with established practice, no reference to the installation procedure is deemed necessary in this Part of BS 5258.

The requirements for controls relate to controls fitted as part of, or supplied with, particular appliances; they do not necessarily provide a complete specification for controls intended for general use.

NOTE The titles of the publications referred to in this standard are listed on the inside back cover.

BS 6332-6:1990 Thermal performance of domestic gas appliances Specification for thermal performance of combined appliances: fanned-circulation ducted-air heater/circulator
BS 5864:1989 Specification for installation in domestic premises of gas-fired ducted-air heaters of rated input not exceeding 60 kW

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 5963:1981 Specification for electrically operated automatic gas shut-off valves
BS 3016:1989 Specification for pressure regulators for liquefied petroleum gases
BS 3955:1986 Specification for electrical controls for household and similar general purposes
BS 1179-6:1980 Glossary of terms used in the gas industry Combustion and utilization including installation at consumers\' premises
BS 567:1973 Specification for asbestos-cement flue pipes and fittings, light quality
BS 6047-1:1981 Flame supervision devices for domestic, commercial and catering gas appliances Specification for heat sensitive type
BS 5482-1:1979 Domestic butane- and propane-gas-burning installations Installations in permanent dwellings
BS 2871-1:1971 Specification for copper and copper alloys. Tubes Copper tubes for water, gas and sanitation
BS 5000-11(1973) : 1973 SPECIFICATION FOR ROTATING ELECTRICAL MACHINES OF PARTICULAR TYPES OR FOR PARTICULAR APPLICATIONS - PART 11: SMALL-POWER ELECTRIC MOTORS AND GENERATORS
BS 5546:1990 Specification for installation of gas hot water supplies for domestic purposes (1st, 2nd and 3rd family gases)
BS 6448-1:1987 Gas governors Specification for pressure governors with nominal connection size up to 50 mm for gas appliances with inlet pressure up to and including 200 mbar
BS 5482-2:1977 Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings
BS 1963:1990 Specification for pressure operated relay valves for domestic, commercial and catering gas appliances
BS 715:1993 Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW
BS 2950:1958 Specification. Cartridge fuse-links for telecommunication and light electrical apparatus
BS 835:1973 Specification for asbestos-cement flue pipes and fittings, heavy quality
BS 4201:1979 Specification for thermostats for gas-burning appliances
BS 5494:1978 Specification for gas taps for domestic and catering appliances
BS 1179:1967 Glossary of terms used in the gas industry
BS 6067:1981 Specification for multifunctional gas controls for domestic, commercial and catering appliances
BS 5482-3:1979 Domestic butane- and propane-gas-burning installations Installations in boats, yachts and other vessels
BS 1362:1973 Specification for general purpose fuse links for domestic and similar purposes (primarily for use in plugs)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.