BS 5266-1:2011
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Emergency lighting Code of practice for the emergency escape lighting of premises
Hardcopy , PDF
English
30-06-2012
31-05-2016
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Consultation and records
5 Illumination for safe movement
6 Emergency escape lighting design
7 Batteries
8 Wiring systems and circuits
9 Choice of appropriate emergency lighting systems
10 Emergency lighting design procedure
11 Certificates and log book
12 Servicing
Annexes
Annex A (informative) - Summary of standards
covering emergency lighting
Annex B (informative) - Measuring illuminance of
emergency lighting
Annex C (informative) - Emergency lighting
classifications
Annex D (informative) - Illuminance for specific
locations
Annex E (informative) - Guidance on illuminance
measurements and calculations
Annex F (informative) - Model completion certificate
Annex G (informative) - Model certificate for
completion of small new installations and
verification of existing installations
Annex H (informative) - Model periodic inspection
and test certificate
Annex I (informative) - Additional guidance on
the compliance checklist and report for
an existing site
Bibliography
Provides recommendations and guidance on the factors that need to be considered in the design of, and the installation and wiring of, electrical emergency escape lighting systems, in order to provide the lighting performance needed for safe movement of people in the event of the supply to normal lighting failing.
| Committee |
EL/1/1
|
| DevelopmentNote |
Supersedes BS 5266-1(2005), BS 5266-10(2008) and 11/30227604 DC. To be read in conjunction with BS EN 1838 and BS EN 50172. (11/2011)
|
| DocumentType |
Standard
|
| Pages |
52
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
This part of BS 5266 gives recommendations and guidance on the factors that need to be considered in the design of, and the installation and wiring of, electrical emergency escape lighting systems, in order to provide the lighting performance needed for safe movement of people in the event of the supply to normal lighting failing. It also gives recommendations for lighting in areas withfixed seating.
This part of BS 5266 is not applicable to dwellings, however its provisions are applicable to common access routes within blocks of flats or maisonettes.
NOTE 1 When the supply to normal lighting of premises fails, emergency lighting might be required. Throughout this standard, reference to “emergency lighting” covers “emergency escape lighting” in particular, but also includes any element of standby lighting which can be used for emergency escape lighting.
NOTE 2 Central power supply systems for electrical emergency lighting systems are specified in BS EN 50171:2001. Luminaires for emergency lighting systems are specified in BS EN 60598-2-22:1998+A2.
NOTE 3 A summary of the hierarchy of standards covering the different aspects of emergency lighting systems is given in Annex A.
A newer version of this standard is available.