• BS 5588-4:1978

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Fire precautions in the design, construction and use of buildings Code of practice for smoke control in protected escape routes using pressurization

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-03-1998

    Language(s):  English

    Published date:  30-06-1978

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Drafting committee
    Code
    1 Scope
    2 References
    3 Definitions
    4 The building
    5 The system
    6 The installation and equipment
    7 General
    Appendix
    A A worked example
    Tables
    1 Pressurization levels
    2 Values of (P) to the power 1/N for N = 2 and N = 1.6
    3 Typical leakage areas for four types of door
    4 Air leakage data for doors
    5 Air leakage data for windows
    6 Values of factor F for various vent sizes
    7 Values of K
    8 Airflow through an open door: staircase only
        pressurized: staircase/accommodation door open
    9 Airflow through an open door: staircase and lift
        lobby pressurized to same level: airflow when one
        lobby/accommodation door is open
    10 Airflow through two open doors: staircase and lift
        lobby pressured to the same level: two lobby doors
        (stairwell/lobby and lobby/accommodation) open on
        same floor
    11 Minimum total length of window cracks (per floor)
        for satisfactory venting of the pressurizing air
    12 Suggestions for choice of venting system
    Figures
    1 Pressurizing staircase only
    2 Deleted
    3 Pressurizing staircase and lift lobby
    4 Leakage paths in series
    5 Leakage paths in parallel
    6 Steps in obtaining the equivalent resistance of a
        combination of series and parallel paths of air
        leakage
    7 Diagram of leakage from lift landing doors
    8 Diagram of airflow conditions listed in table 8
    9 Diagram of airflow conditions listed in table 9
    10 Diagram of airflow conditions listed in table 10
    11 Plan of building for worked example

    Abstract - (Show below) - (Hide below)

    Recommendations for a method for keeping protected escape routes in buildings clear of smoke by pressurizing the escape routes. The method is an alternative to the natural ventilation required by CP 3:Ch IV and certain building acts and regulations.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/14
    Development Note BS DRAFT 92/39700 DC
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 5588-11:1997 Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings
    BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
    BS 5720:1979 Code of practice for mechanical ventilation and air conditioning in buildings
    BS 5588-10:1991 Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes
    BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
    BS 5588-2:1985 Fire precautions in the design, construction and use of buildings Code of practice for shops
    BS 5588-7:1997 Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings
    BS 5588-5:1991 Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts
    BS 6701-1:1990 Code of practice for installation of apparatus intended for connection to certain telecommunication systems General recommendations
    BS 7083:1996 Guide to the accommodation and operating environment for information technology (IT) equipment
    BS 5588-9:1989 Fire precautions in the design, construction and use of buildings Code of practice for ventilation and air conditioning ductwork
    BS 8200:1985 Code of practice for design of non-loadbearing external vertical enclosures of buildings
    BS 5588-5:1986 Fire precautions in the design and construction of buildings. Code of practice for firefighting stairways and lifts
    BS 6701-1:1986 Code of practice for installation of apparatus intended for connection to certain telecommunication systems General recommendations
    BS 5588-3:1983 Fire precautions in the design, construction and use of buildings Code of practice for office buildings
    BS 5234-1:1992 Partitions (including matching linings) Code of practice for design and installation

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5588-2:1985 Fire precautions in the design, construction and use of buildings Code of practice for shops
    BS 5839-1:1988 Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing
    BS 5588-3:1983 Fire precautions in the design, construction and use of buildings Code of practice for office buildings
    BS CP3:CH4-1(1971) : AMD 2708 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - PRECAUTIONS AGAINST FIRE - FLATS AND MAISONETTES - (IN BLOCKS OVER TWO STOREYS)
    BS 5588-1:1990 Fire precautions in the design, construction and use of buildings Code of practice for residential buildings
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective