BS 5608:1993
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specification for preformed rigid polyurethane (PUR) and polyisocyanurate (PIR) foams for thermal insulation of pipework and equipment
Hardcopy , PDF
02-01-2024
English
15-11-1993
Committees responsible
Foreword
Specification
1. Scope
2. References
3. Designation
4. Composition
5. Physical properties
6. Dimensions and dimensional tolerances
7. Condition and appearance
8. Sampling
9. General requirements
10. Marking
Annexes
A. (normative) Method of preparation of a moulded
flat test piece
B. (informative) Guidance on thermal conductivity
design and 3 day values
C. (normative) Method of test for compression
characteristics
D. (normative) Method of test for dimensional stability
E. (informative) Burning properties of rigid PUR and
PIR foam and recommendations for use
F. (informative) Notes for designers
Tables
1. Designation codes for thermal conductivity
2. Physical property requirements
3. Dimensional tolerances for pipe sections and lags
4. Dimensional tolerances for slabs
List of references
Includes a requirement for the thermal conductivity to be designated by the manufacturer.
Committee |
B/540
|
DevelopmentNote |
Supersedes 92/46013 DC and BS 5608(1986) (08/2005) Reviewed and confirmed by BSI, December 2009. (11/2009)
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
This British Standard specifies the composition, physical properties and dimensional tolerances for preformed rigid polyurethane (PUR) and polyisocyanurate (PIR) foams for the thermal insulation of pipework and equipment. It applies to slabs, cut and moulded pipe sections and radiused and bevelled lags. The nominal temperature range f or which the insulation material is suitable is − 180 °C to + 140 °C (see Annex F).
NOTE 1 No values are specified in this standard for the length, bore and outside diameter of pipe sections and lags or for the length and width of slab stock; these should be as specified by the purchaser.
BS 2972:1989 | Methods of test for inorganic thermal insulating materials |
BS 4370-2:1973 | Methods of test for rigid cellular materials Methods 6-10 |
BS 4735:1974 | Laboratory method of test for assessment of the horizontal burning characteristics of specimens no larger than 150 mm x 50 mm x 13 mm (nominal) of cellular plastics and cellular rubber materials when subjected to a small flame |
BS 6336:1982 | Guide to development and presentation of fire tests and their use in hazard assessment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.