• BS 5618:1985

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Code of practice for thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with urea-formaldehyde (UF) foam systems

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  02-01-2024

    Language(s):  English

    Published date:  31-07-1985

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Committees responsible
    Code of practice
    1. Scope
    2. Definitions
    3. Suitability of cavity walls for insulation
    4. Material composition
    5. Thermal performance of installed foam
    6. The filling process
    7. Installation of the UF foam system
    8. Post-installation activities
    9. Records
    10. Declaration
    Appendices
    A. Criteria for suitability of external cavity walls
    B. Natural stones used in the construction of
         masonry walls
    C. Calculation of the exposure index E of a building
         (tabular method)
    D. Calculation of the exposure index E (formula
         method)
    E. Driving-rain index
    F. Comparison of methods for assessing exposure to
         wind-driven rain
    G. Formaldehyde
    H. Flue checks for appliances of rated input not
         exceeding 60 kW
    J. Properties of the installed (UF) foam
    K. Methods for determination of cavity width
    Tables
    1. Quality checks on site during or prior to
         installation
    2. Geographic factor G
    3. Topographic factor T
    4. Terrain roughness factor R
    5. Topographic factor S
    6. Equations for Bc
    7. Comparisons between exposure values in DD 93 and
         in this code
    Figures
    1. Staggered drilling pattern (representing maximum
         spacing)
    2. Drilling and filling patterns at damp proof course
         and party lines
    3. Unit area plan
    4. Overall pattern of filling for a nominal 50 mm
         width cavity
    4a. Types of rubble walling
    5. Maximum height of external cavity wall
    6. Effective height of a partially protected cavity
         wall
    7. Height of location for buildings on or close to
         steeply rising ground
    8. Relationship between the exposure index used in
         this code and the maximum directional spell index
         in DD 93
    9. Measurement of cavity width
    10. Estimation of cavity width
    Maps
    Key to driving-rain index maps 1 to 30
    1-30 Driving-rain index
    31 Annual mean driving-rain index 'roses'

    Abstract - (Show below) - (Hide below)

    This edition updates the selection procedure for suitable properties and significantly tightens the requirements for the installation procedure.

    Scope - (Show below) - (Hide below)

    This British Standard code of practice describes recommendations for the installation of urea-formaldehyde (UF) foam systems which are dispensed on site, to fill the cavities of suitably situated and constructed external walls of maximum height 12 m, which have masonry or concrete inner and outer leaves, thereby providing additional thermal insulation to such walls. It defines what are suitably situated and constructed external walls and indicates essential procedures and precautions for the filling process. Walls built of random rubble are not covered by this code.

    NOTE The titles of the publications referred to in this code are listed on the inside back cover.

    General Product Information - (Show below) - (Hide below)

    Committee B/540
    Development Note Supersedes 85/35766 DC, 87/42098 DC, 91/40404 DC and BS 5618(1978) (08/2005) Reviewed and confirmed by BSI, November 2012. (10/2012)
    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 8211-1:1988 Energy efficiency in housing Code of practice for energy efficient refurbishment of housing
    S.R. 325:2013+A2:2018/AC:2019 RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES IN IRELAND TO EUROCODE 6
    BS 5628-3:2005 CODE OF PRACTICE FOR THE USE OF MASONRY - PART 3: MATERIALS AND COMPONENTS, DESIGN AND WORKMANSHIP
    BS 5628-3:2001 Code of practice for use of masonry Materials and components, design and workmanship
    10/30168896 DC : 0 PD 6697 - RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES TO BS EN 1996-1-1 AND BS EN 1996-2
    BS 8208-1:1985 Guide to assessment of suitability of external cavity walls for filling with thermal insulants Existing traditional cavity construction
    BS 8104:1992 Code of practice for assessing exposure of walls to wind-driven rain
    PD 6697:2010 Recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN 1996-2
    I.S. 325-2:1995 CODE OF PRACTICE FOR USE OF MASONRY - PART 2: MASONRY CONSTRUCTION
    BS 5617:1985 Specification for urea-formaldehyde (UF) foam systems suitable for thermal insulation of cavity walls with masonry or concrete inner and outer leaves
    05/30131954 DC : DRAFT APR 2005 BS 5628-3 - CODE OF PRACTICE FOR THE USE OF MASONRY - PART 3: MATERIALS AND COMPONENTS, DESIGN AND WORKMANSHIP

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 5440-1:1978 Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases). Flues
    BS 5628-3:1985 Code of practice for use of masonry Materials and components, design and workmanship
    BS CP3:CH5-2(1972) : AMD 7908 CODE OF BASIC DATA FOR THE DESIGN OF BUILDINGS - LOADING - WIND LOADS
    BS 5617:1985 Specification for urea-formaldehyde (UF) foam systems suitable for thermal insulation of cavity walls with masonry or concrete inner and outer leaves
    BS DD93(1984) : 1984 METHODS FOR ASSESSING EXPOSURE TO WIND-DRIVEN RAIN
    BS 8208-1:1985 Guide to assessment of suitability of external cavity walls for filling with thermal insulants Existing traditional cavity construction
    BS 5262:1976 Code of practice. External rendered finishes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective