BS 5654-4:1979
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Stabilized power supplies, d.c. output Tests other than radio-frequency interference
Hardcopy , PDF
20-04-2012
English
28-02-1979
National foreword
Cooperating organizations
1 General remarks
2 General definitions
3 Instrumentation
4 Conditions of measurement
5 Set of test data
6 Time separation
Section one - Load effect
7 Definition
8 Conditions of measurement
9 Equipment required
10 Set-up and procedure (voltage-stabilized power
supplies)
11 Set-up and procedure (current-stabilized power
supplies)
12 Presentation of results
13 Alternates, precautions and error analysis
Section two - Source effect
14 Definition
15 Conditions of measurement
16 Equipment required
17 Set-up and procedure (voltage-stabilized power
supplies)
18 Set-up and procedure (current-stabilized power
supplies)
19 Presentation of results
20 Alternates, precautions and error analysis
Section three - Periodic and random deviation
(PARD)
21 Definition
22 Conditions of measurement
23 Equipment required
24 Set-up and procedure
25 Alternates, precautions and error analysis
Section four - Drift
26 Definition
27 Conditions of measurement
28 Equipment required
29 Set-up and procedure
30 Alternates, precautions and error analysis
Section five - Output impedance
31 Definition
32 Conditions of measurement
33 Equipment required
34 Set-up and procedure for voltage-stabilized power
supplies
35 Set-up and procedure for current-stabilized power
supplies
36 Alternates, precautions and error analysis
Section six - Temperature effect
37 Definition
38 Conditions of measurement
39 Equipment required
40 Set-up and procedure
41 Alternates, precautions and error analysis
Section seven - Transient performance measurement
42 General
43 Scope
44 Conditions of measurement
45 Equipment required
46 Set-up and procedure
47 Alternates, precautions and error analysis
Section eight - Settling effects
48 Definition
49 Conditions of measurement
50 Equipment required
51 Set-up and procedure
52 Alternates, precautions and error analysis
Section nine - Other individual effects
53 General
54 Conditions of measurement
55 Equipment required
56 Set-up and procedure
57 Alternates, precautions and error analysis
Section ten - Combined effects
58 Definition
59 Conditions of measurement
60 Equipment required
61 Set-up and procedure
62 Alternates, precautions and error analysis
Section eleven - Total effect
63 Definition
64 Conditions of measurement
65 Equipment required
66 Set-up and procedure
Section twelve - Measurement of quantities related
to the source
67 Definition
68 Conditions of measurement
69 Equipment required
70 Set-up and procedure
71 Alternates, precautions and error analysis
Section thirteen - Capacitance to source terminals
72 Definition
73 Conditions of measurement
74 Equipment required
75 Set-up and procedure
Section fourteen - Capacitance to frame
76 Definition
77 Conditions of measurement
78 Equipment required
79 Set-up and procedure
Section fifteen - Common-mode current
80 Definition
81 Equipment required
82 Set-up and procedure
83 Alternates, precautions and error analysis
Section sixteen - Boundary condition measurements
84 General
85 Threshold measurement
86 Conditions of measurement
87 Equipment required
88 Set-up and procedure for voltage-stabilized power
supplies
89 Set-up and procedure for current-stabilized power
supplies
90 Measurement of maximum limited values
91 Measurement of the value of the bounded output
quantity for the extremity of load
92 Measurement of the peak value of the bounded output
quantity
Section seventeen - Sound level
93 Definition
94 Conditions of measurement
95 Equipment required
96 Set-up and procedure
97 Calculation of sound level
Section eighteen - Control effects
98 General
99 Conditions of measurement
100 Equipment required
101 Set-up and procedure
Figures
Tests for stabilized power supplies designed to supply d.c. power from an a.c. or d.c. source to laboratories, industrial equipment etc.
Committee |
PEL/22
|
DevelopmentNote |
Also numbered as IEC 60478-4 Supersedes 77/28037 DC (08/2005)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
BS 5654-2:1979 | Stabilized power supplies, d.c. output Method of specifying rating and performance |
BS 6688:1986 | Method for specifying requirements for low voltage power supplies, switching type, d.c. output |
BS 5654-1:1979 | Stabilized power supplies, d.c. output Terms and definitions |
BS 4197(1967) : LATEST | A PRECISION SOUND LEVEL METER |
BS 5148:1975 | Method for specifying the performance of stabilized power supply apparatus |
BS 5654-2:1979 | Stabilized power supplies, d.c. output Method of specifying rating and performance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.