• BS 5655-13:1995

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Lifts and service lifts Recommendations for vandal resistant lifts

    Available format(s):  Hardcopy, PDF

    Superseded date:  20-06-2005

    Language(s):  English

    Published date:  15-12-1995

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Committees responsible
    Foreword
    Recommendations
    1 Scope
    2 References
    3 Definitions
    4 Machine room
    5 Well ventilation
    6 Landing door construction
    7 Car door construction
    8 Landing and car door installation
    9 Locking of car doors
    10 Door reversal mechanism
    11 Sight guards
    12 Astragals
    13 Sills and their fixings
    14 Emergency unlocking of landing doors
    15 Car bodywork
    16 Car illumination
    17 Car control panel
    18 Car position, and other, indicators within the car
    19 Car roof trap doors
    20 Car ventilation
    21 Landing fixtures
    22 Alarm devices
    23 Steel work
    24 General guidance
    Annex
    A (normative) Impact testing of vision panels,
        pressels and indicators
    List of references

    Abstract - (Show below) - (Hide below)

    Gives advice and performance criteria that will increase the vandal resistance of lifts.

    Scope - (Show below) - (Hide below)

    This Part of BS 5655 supplements BS 5655-1 and BS 5655-2 with additional recommendations and performance criteria intended to increase the vandal resistance of lifts. It does not cover such measures as improved building security, enhanced aesthetics, etc. which might also be usefully considered.

    It is assumed that car and landing doors are operated automatically with characteristics taken from Tables 1 to 4 of BS 5655-5:1989.

    NOTE A totally enclosed well, and car and landing doors which are operated automatically, are prerequisites to vandal resistance. This British Standard assumes that the more restrictive access is to equipment, the less likely will be the occurrence of vandalism.

    General Product Information - (Show below) - (Hide below)

    Committee MHE/4
    Development Note Supersedes 94/706353 DC and BS DD197(1990). (04/2005) Inactive for the new design. (12/2011)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 5655-6:2002 Lifts and service lifts Code of practice for the selection and installation of new lifts

    Standards Referencing This Book - (Show below) - (Hide below)

    ASME A17.1-2016/CSA B44-16 Safety code for elevators and escalators (Bi-national standard, with ASME A17.1)
    BS 5655-6:1990 Lifts and service lifts Code of practice for selection and installation
    BS 3621:1980 Specification for thief resistant locks
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications