• There are no items in your cart

BS 5679:1979

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Method (precision) for free-field calibration of one-inch standard condenser microphones by the reciprocity technique

Available format(s)

Hardcopy , PDF

Superseded date

15-07-1996

Language(s)

English

Published date

29-12-1978

National foreword
Cooperating organizations
1. Scope
2. Object
3. Explanation of terms
3.1 Open-circuit voltage
3.2 Free-field sensitivity of a microphone
3.3 Electrical impedance of a microphone
3.4 Acoustic impedance of a microphone
3.5 Acoustic centre of a microphone
3.6 Principal axis of a microphone
3.7 Free-field conditions
3.8 Reciprocal microphone
4. Principles of a free-field reciprocity calibration
4.1 General
4.2 Acoustic conditions
4.3 Receiving and transmitting characteristics of a
      microphone
4.4 Reciprocity procedure
4.5 Attenuation of sound in air
4.6 Final expressions for the free-field sensitivity
5. Absolute accuracy of calibration
5.1 General
5.2 Accuracy of factors influencing a calibration
5.3 Overall accuracy
6. Calibration methods and equipment
6.1 Free field
6.2 Reference configuration of ground shield
6.3 Insert voltage technique
6.4 Acoustic loading
6.5 Dependence on static pressure
6.6 Polarizing voltage
6.7 Acoustic centre of the microphone
6.8 Maximum generator voltage
6.9 Noise
Appendix A - Tables of air attenuation
Appendix B - Values of the position of the acoustic
centre of the microphone

Method for calibration of microphones used as laboratory standards.

Committee
EPL/29
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
IEC 60486:1974 Identical

BS 5941:1980 Specification for values for the difference between free-field and pressure sensitivity levels for one-inch standard condenser microphones
BS 5677:1979 Method (precision) for pressure calibration of one-inch standard condenser microphones by the reciprocity technique

View more information
€216.35
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.