BS 5724-2.12(1990) : 1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR LUNG VENTILATORS
Hardcopy , PDF
15-11-1997
English
01-01-1990
Committees responsible
National foreword
Section one: General
Clause
1. Scope and object
1.1 Scope
2. Terminology and definitions
3. General requirements
4. General requirements for tests
5. Classification
6. Identification, marking and documents
6.8 Accompanying documents
7. Power input
Section two: Safety requirements
8. Basic safety categories
9. Removable protective means
12. Single fault condition
Section three: Protection against electric shock hazards
17. Insulation and protective impedances
18. Earthing and potential equalization
19. Continuous leakage currents and patient auxiliary
currents
20. Dielectric strength
Section four: Protection against mechanical hazards
Section five: Protection against hazards from unwanted
or excessive radiation
Section six: Protection against the hazards of explosions
in medically used rooms
Section seven: Protection against excessive temperatures,
fire and other hazards, such as human errors
42. Excessive temperatures
43. Fire prevention
44. Overflow, spillage, leakage, humidity, ingress of
liquids, cleaning, sterilization and disinfection
44.3 Spillage
49. Interruption of the power supply
Section eight: Accuracy of operating data and protection
against incorrect output
Section nine: Fault conditions causing overheating and/
or mechanical damage; environmental tests
Section ten: Constructional requirements
56. Components and general assembly
57. Mains parts, components and layout
Appendix
AA. Rationale
Describes safety requirements for LUNG VENTILATORS with electrical devices designed for medical use. Non-electrical requirements, and some safety requirements, are given in ISO 5369 - 1977: Breathing machines for medical use - Lung ventilators. Includes sections on protection against electric shock, mechanical hazards, excess radiation, explosions in medically used rooms, excess temperatures, fire etc., accuracy of operating data and protection against incorrect output, fault conditions, mechanical damage, environmental tests, and constructional requirements.
Committee |
HCC/46
|
DevelopmentNote |
IMPLEMENTS CENELEC HD 395.2.12
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
IEC 60601-2-12:2001 | Identical |
BS 5724-2.13(1990) : 1990 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR ANAESTHETIC MACHINES |
BS 5724-2.13(1990) : 1990 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR ANAESTHETIC MACHINES |
ISO 5369:1987 | Breathing machines for medical use Lung ventilators |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.