• BS 5724-2.16(1989) : 1989

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR HAEMODIALYSIS EQUIPMENT

    Available format(s):  Hardcopy, PDF

    Superseded date:  15-07-1998

    Language(s):  English

    Published date:  01-01-1989

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National foreword
    Committees responsible
    Introduction
    Section one: General
    1. Scope and object
    2. Terminology and definitions
    6. Identification, marking and documents
    Section two: Safety requirements
    12. Single fault condition
    Section three: Protection against electric shock hazards
    19. Continuous leakage currents and patient auxiliary
         currents
    20. Dielectric strength
    Section four: Protection against mechanical hazards
    Section five: Protection against hazards from unwanted
    or excessive radiation
    Section six: Protection against the hazards of explosions
    in medically used rooms
    Section seven: Protection against excessive temperatures,
    fire and other hazards, such as human errors
    44. Overflow, spillage, leakage, humidity, ingress of
         liquids, cleaning, sterilization and disinfection
    45. Pressure vessels and parts subject to pressure
    46. Human errors
    49. Interruption of the POWER SUPPLY
    Section eight: Accuracy of operating data and protection
    against incorrect output
    50. Accuracy of operating data
    51. Protection against incorrect output
    Section nine: Fault conditions causing overheating and/
    or functional damage; environmental tests
    Section ten: Constructional requirements
    56. Components and general assembly
    57. MAINS PARTS, components and layout
    Appendix AA. Rationale for the particular requirements
                  of this standard

    Abstract - (Show below) - (Hide below)

    Sets out safety requirements for single PATIENT single pass HAEMODIALYSIS EQUIPMENT for use either by medical staff or under the supervision of medical expertise, including patient operated HAEMODIALYSIS EQUIPMENT. Excludes blood lines, HAEMODIALYSERS, DIALYSING FLUID CONCENTRATE and water purification EQUIPMENT. Includes sections on protection against electric shock, mechanical hazards, excess radiation, explosions in medically used rooms, excess temperatures, fire, etc., accuracy of operating data and protection against incorrect output, fault conditions and constructional requirements.

    General Product Information - (Show below) - (Hide below)

    Committee HCC/23
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC TR 60513:1994 Fundamental aspects of safety standards for medical electrical equipment
    BS 3930-1(1987) : AMD 8072 CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND OTHER MEDICAL EQUIPMENT - SPECIFICATION FOR GENERAL REQUIREMENTS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective