BS 5724-2.44(1999) : 1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE SAFETY OF X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY
08-08-2002
23-11-2012
Introduction
Section 1: General
1 Scope and object
2 Terminology and definitions
6 Identification, marking and documents
Section 2: Environmental Conditions
Section 3: Protection against Electric Shock Hazards
Section 4: Protection against Mechanical Hazards
22 Moving parts
27 Pneumatic and hydraulic power
Section 5: Protection against Hazards from Unwanted or
Excessive Radiation
29 X-radiation
Section 6: Protection against Hazards of Ignition of
Flammable Anaesthetic Mixtures
Section 7: Protection against Excessive Temperatures
and Other Safety Hazards
Section 8: Accuracy of Operating Data and Protection
against Hazardous Output
50 Accuracy of operating data
Section 9: Abnormal Operation and Fault Conditions:
Environmental Tests
Section 10: Constructional Requirements
Table 101 - Half-value layers in CT scanners
Figure 101 - Coordinate system
Annex AA (normative) Terminology - Index of defined terms
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Annex ZB (informative) Other international publications
mentioned in this standard with the
references of the relevant European
publications
Applicable to x-ray equipment for computed tomography (CT scanners). Does not cover safety requirements for HV-generators which will be the subject in another standard.
Committee |
CH/73
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
Standards | Relationship |
IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV | Identical |
BS EN 60601-2-44 : 2009 | Identical |
EN 60601-2-44:2009/A2:2016 | Identical |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
ISO 2092:1981 | Light metals and their alloys Code of designation based on chemical symbols |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-32:1994 | Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment |
IEC 60601-1-3:2008+AMD1:2013 CSV | Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment |
IEC 60601-1-1:2000 | Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems |
IEC 60601-1-4:1996+AMD1:1999 CSV | Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems |