• There are no items in your cart

BS 5857-2.1:1980

Current

Current

The latest, up-to-date edition.

Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow General

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-1980

National foreword
Cooperating organizations
Methods
0 Introduction
1 Scope and field of application
2 Vocabulary and symbols
3 Units
4 Choice of method
5 Choice of tracer
6 Choice of measuring length and adequate mixing
   distance
7 Errors
Annex
   Distribution table of chi squared (Pearson's law)
Figures
1 Theoretical results
2 Reynolds number effect on mixing distance
3 Experimental results

Compares the dilution method with the method based on transit time measurement. Also covers choice of tracers and measuring/mixing lengths.

This International Standard deals with the measurement of gas flow in conduits by using tracer methods.

In a steady flow of compressible fluid, the only conservative parameter is the mass rate of flow qm. Therefore the whole of this International Standard will refer to mass rate of flow qm.

However, for those fluids for which the composition (and therefore, the mass density) may not be known accurately, the volume rate of flow qv could be measured, it being understood that this volume rate of flow is only valid for the conditions of temperature and pressure at which it has been measured.

This International Standard applies to flow measurement in conduits into which a tracer can be injected in such a way that effective mixing in single phase with the gas flowing in the pipe can be achieved.

The fluid in the conduit can be a mixture of several gases provided the thermodynamic state and conditions of flow of this mixture are well defined.

Two fundamental test procedures are used:

  • — The first, known as the constant rate injection method, is based on the dilution principle: a tracer solution is injected into the conduit and the dilution (ratio) of this tracer in the gas flowing in the conduit is determined, this dilution being proportional to the rate of flow.
  • — The second is a method of measurement of the transit time (formerly called Allen velocity method): the tracer is injected into the conduit and the time taken by the tracer to travel a specified length between two cross-sections in each of which it is detected, is measured.

The advantages and disadvantages of these two methods are considered in clause 4. The distance between injection and measuring sections shall be sufficient to achieve mixing of the tracer with the gas flowing in the conduit according to the methods; the adequate mixing distance is considered in clause 6.

A large number of different tracers may be used, such as radioactive or non-radioactive, mineral or organic materials. The choice of tracer depends on the circumstances of the measurement (see clause 5). The uncertainty of the measurements may be less than 1 % under good conditions (see clause 7).

Committee
CPI/30/5
DevelopmentNote
Also numbered as ISO 4053-1 Supersedes 76/29641 DC (08/2005)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current

BS 5857-2.4:1980 Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of gas flow Transit time method using radioactive tracers
BS 0-3:1991 A standard for standards Guide to drafting and presentation of British Standards

BS 5875:1980 Glossary of terms and symbols for measurement of fluid flow in closed conduits

View more information
€155.16
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.