Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Exchange of information and planning
5 Appliances
6 Materials and components
7 Location
8 Ventilation
9 Flueing
10 Appliance fixing
11 Fire and related safety precautions
12 Gas supply
13 Electricity supplies and wiring
14 Commissioning
15 Instructions and use of fireguards
16 Advice to be given to the user
Annex A (informative) Calculation of clearance flue flow
Bibliography

Describes installation and maintenance requirements for open flued decorative fuel effect gas appliances of heat input not exceeding 20 kW (see Note 2) burning 2nd and 3rd family gases in rooms or internal spaces in domestic (see Note 4) or commercial premises, including public houses and restaurants.

Committee
GSE/30
DevelopmentNote
Supersedes 03/320606 DC. (04/2005) Also available as part of BS KIT 174. (05/2005)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Current

This part of BS5871 specifies installation and maintenance requirements for open flued decorative fuel effect gas appliances of heat input not exceeding 20kW (see Note2) burning 2nd and 3rd family gases in rooms or internal spaces in domestic (see Note4) or commercial premises, including public houses and restaurants.

The provisions contained within this standard cover the selection of a suitable appliance, the ventilation and flueing requirements, and other measures necessary to ensure a safe installation.

This standard applies to the installation of decorative fuel effect gas appliances in builder’s openings, fireplace recesses, flue boxes or under associated independent canopies. (See Figure5.) It does not cover the installation of flueless or room-sealed appliances.

This standard is not applicable to mobile and portable appliances in conformity with BSEN449 or to appliances in touring caravans.

NOTE1 Attention is drawn to the foreword concerning fuel effect appliances which burn gas for a decorative effect. The only types of such appliance covered by this part of BS5871 are those detailed in b) of the Commentary and recommendations on Clause5 of this standard. Further guidance in this respect is given in Figure1.

NOTE2 Heat inputs in this document are based on net calorific value. Figures based on gross calorific value are given in parenthesis where deemed necessary. [See also Clause5, commentary and recommendations b).]

NOTE3 Attention is drawn to the foreword concerning the installation of used appliances.

NOTE4 As well as normally constructed dwellings, domestic premises include any permanently sited caravan holiday homes, residential park homes and permanently moored boats. See IGE/UP/8 [8].

NOTE5 Appliances of over 20kW: although many of the requirements within this standard will equally apply to appliances with a rated heat input in excess of 20kW, additional or alternative requirements may also be applicable in order to achieve a safe installation. Reference should be made to the Building Regulations and supporting guidance or requirements thereto.

BS 476-4:1970 Fire tests on building materials and structures Non-combustibility test for materials
BS 1289-1:1986 Flue blocks and masonry terminals for gas appliances Specification for precast concrete flue blocks and terminals
BS 7435-2:1991 Fibre cement flue pipes, fittings and terminals Specification for heavy quality fibre cement flue pipes, fittings and terminals
PD 6501-1:1982 The preparation of British Standards for building and civil engineering Guide to the types of British Standard, their aims, relationship, content and application
BS 6539:1984 Specification for fireguards for use with solid fuel appliances
BS 7977-1:2002 Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors
BS EN 449 : 2002 SPECIFICATION FOR DEDICATED LIQUEFIED PETROLEUM GAS APPLIANCES - DOMESTIC FLUELESS SPACE HEATERS (INCLUDING DIFFUSIVE CATALYTIC COMBUSTION HEATERS)
BS 6461-1:1984 Installation of chimneys and flues for domestic appliances burning solid fuel (including wood and peat) Code of practice for masonry chimneys and flue pipes
BS 5482-2:1977 Domestic butane- and propane-gas-burning installations Installations in caravans and non-permanent dwellings
BS 7671(2001) : 2001 AMD 14905 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
BS 715:1993 Specification for metal flue pipes, fittings, terminals and accessories for gas-fired appliances with a rated input not exceeding 60 kW
BS EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
BS EN 1443:2003 Chimneys. General requirements
CR 1472:1997 General guidance for the marking of gas appliances
BS EN 1856-1:2009 Chimneys. Requirements for metal chimneys System chimney products
BS 6778:1986 Specification for fireguards for use with portable, free-standing or wall-mounted heating appliances
PD 6516:1987 Guide to guarding fires and heating appliances
BS EN 1856-2:2009 Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.